CJC-1295 + Ipamorelin (5mg/5mg) · Research brief
CJC-1295 No DAC Research Vial: Purity, HPLC and COA
Short answer
CJC-1295 no DAC is a synthetic analog of the first 29 amino acids of growth hormone releasing hormone, built with four sequence substitutions and without the drug affinity complex that defines the albumin binding version, and it is supplied as a lyophilized powder for laboratory research whose identity and purity are established by reverse phase HPLC and mass spectrometry and…
CJC-1295 no DAC is a synthetic analog of the first 29 amino acids of growth hormone releasing hormone, built with four sequence substitutions and without the drug affinity complex that defines the albumin binding version, and it is supplied as a lyophilized powder for laboratory research whose identity and purity are established by reverse phase HPLC and mass spectrometry and recorded on a lot specific certificate of analysis. Real Peptides supplies the compound as a research use only material, catalogued at CJC-1295 No-DAC, and publishes independent third party certificates of analysis for every batch at /coas/, indexed so a lot number printed on a vial label can be matched to the document that describes that batch.
What is CJC-1295 no DAC, and what does the missing DAC refer to?
CJC-1295 no DAC is the tetrasubstituted growth hormone releasing hormone fragment on its own, without the conjugating chemistry that the full CJC-1295 construct carries. DAC stands for drug affinity complex, an appended chemical group designed to form a covalent bond with a free thiol on circulating serum albumin. In the albumin binding construct, that group is commonly described as a maleimide bearing moiety attached through a linker at the carboxyl end of the peptide chain, which allows the peptide to attach itself to a large plasma protein and persist far longer in circulation than a free peptide of the same sequence.
Strip the conjugating group away and what remains is a short, unconjugated peptide of 29 residues with a free carboxyl terminal amide. It carries the same receptor targeting sequence, so it engages the same receptor, but it has no mechanism for anchoring to albumin and therefore no engineered persistence. The chemical difference is small in mass but large in behaviour: one version is designed for an extended presence in a biological matrix, the other is not.
That distinction matters in procurement because catalog names are not always precise. Listings may read CJC-1295 DAC, CJC-1295 with DAC, CJC-1295 DAC free, or CJC-1295 without DAC, and the two materials are different molecular entities with different masses and different chromatographic retention. A certificate of analysis resolves the ambiguity, because the mass recorded by mass spectrometry for the conjugated construct cannot be confused with the mass of the unconjugated 29 residue chain. Background on the wider CJC-1295 family is collected at CJC-1295.
Is CJC-1295 without DAC the same compound as Mod GRF 1-29?
Yes. CJC-1295 without DAC and Mod GRF 1-29 are two names for the same molecule, and a third name, modified GRF (1-29), appears in the same context. GRF stands for growth hormone releasing factor, an older designation for growth hormone releasing hormone, and 1-29 identifies the fragment: the first 29 residues of the 44 residue native hormone, which is the shortest portion that retains full activity at the receptor.
Sermorelin is the unmodified GHRH(1-29) amide. Mod GRF 1-29 is that same fragment with four amino acid replacements. The naming overlap arose because the modified fragment was the peptide backbone used in the CJC-1295 construct; when the conjugating group is omitted, the remaining molecule is the modified fragment itself. Vendors who list the fragment under the CJC-1295 heading are describing the backbone rather than the complete conjugate.
For a laboratory, the practical consequence is that purchase records, inventory labels and published method descriptions may not use the same name for the same vial. Identity should be tracked by sequence and measured mass rather than by trade name, since those two attributes are unambiguous and appear on the analytical documentation. A certificate that prints the full one letter or three letter sequence alongside the mass spectrometry result lets a receiving laboratory confirm, without correspondence, that the material in hand is the modified 29 residue fragment and not sermorelin, not the albumin binding conjugate, and not a truncated variant.
What is the amino acid sequence, and why were four residues substituted?
The sequence is Tyr-D-Ala-Asp-Ala-Ile-Phe-Thr-Gln-Ser-Tyr-Arg-Lys-Val-Leu-Ala-Gln-Leu-Ser-Ala-Arg-Lys-Leu-Leu-Gln-Asp-Ile-Leu-Ser-Arg, with the carboxyl terminus present as an amide rather than a free acid. Four positions differ from the native GHRH(1-29) amide sequence, and each substitution addresses a recognised chemical liability of the parent peptide.
Position 2 carries D-alanine in place of L-alanine. Native growth hormone releasing hormone is cleaved near its amino terminus by dipeptidyl peptidase IV, an exopeptidase that removes the first two residues and in doing so destroys the receptor binding epitope. Substituting the D enantiomer at that position is the standard approach to reducing recognition by that enzyme class, and it is the single modification most often credited with the longer survival of the modified fragment compared with the unmodified one in biological matrices.
Position 8 carries glutamine where the native sequence carries asparagine. Asparagine residues are prone to deamidation and to the formation of succinimide intermediates, particularly in solution and at elevated pH, which generates isoaspartate containing variants with altered activity. Position 15 carries alanine in place of glycine, a change associated in structure activity work on this peptide family with improved helical character in the central region. Position 27 carries leucine in place of methionine, which removes the only thioether side chain and with it the most readily oxidised residue in the sequence. Taken together, the four changes are chemical stabilisation choices, two aimed at enzymatic degradation and two aimed at spontaneous chemical degradation of the solid and of the molecule in solution.
How does the peptide interact with the growth hormone releasing hormone receptor?
The modified fragment binds the growth hormone releasing hormone receptor, a class B G protein coupled receptor expressed on pituitary somatotroph cells. Class B receptors recognise medium length peptide ligands through a two domain mechanism: the carboxyl terminal portion of the ligand docks into the large extracellular domain, which positions the amino terminal portion of the ligand into the transmembrane helical bundle where it triggers the conformational change that activates signalling. The amino terminus of GHRH is therefore the activating end, which explains why removal of the first two residues by dipeptidyl peptidase IV abolishes activity and why protecting that end is the central design goal of the modified fragment.
The activated receptor couples principally to Gs, stimulating adenylyl cyclase and raising intracellular cyclic AMP. Protein kinase A activity follows, with downstream phosphorylation of transcription factors including CREB, and increased transcription of the growth hormone gene under the control of the pituitary specific transcription factor Pit-1. Alongside the transcriptional arm, the cyclic AMP signal promotes calcium entry and the release of stored growth hormone from secretory granules, which is why GHRH stimulation produces both an acute secretory response and a slower increase in hormone synthesis and somatotroph proliferation.
The system is held in balance by somatostatin, which acts through inhibitory G proteins at the same cell and suppresses cyclic AMP, and by negative feedback from insulin like growth factor I generated in the liver in response to circulating growth hormone. Any analog acting at this receptor therefore operates within a regulated axis rather than as a simple switch, and the magnitude of a response measured in a model depends on the somatostatin tone and feedback state of that model at the time of measurement.
What does the published clinical literature on CJC-1295 report?
The published human literature under the CJC-1295 name concerns the albumin binding construct rather than the unconjugated fragment. A 2006 report in The Journal of Clinical Endocrinology and Metabolism, titled 'Prolonged stimulation of growth hormone (GH) and insulin-like growth factor I secretion by CJC-1295, a long-acting analog of GH-releasing hormone, in healthy adults' (study), describes healthy adult volunteers who received assigned trial amounts of the conjugated analog across ascending study arms, with serial measurement of plasma growth hormone and insulin like growth factor I. The report describes increases in mean growth hormone and insulin like growth factor I concentrations that scaled with the assigned amounts and persisted over a period of days, an estimated elimination half life in the range of 5.8 to 8.1 days, and preservation of pulsatile growth hormone secretion rather than a flat elevation.
The limits of that report are straightforward and should travel with any citation of it. The participants were healthy adults rather than a population with a disorder of the growth axis; the sample was small and the follow up short; the endpoints were circulating hormone concentrations, which are intermediate biochemical measures rather than clinical outcomes; and, most importantly for anyone working with the unconjugated fragment, the molecule studied carried the albumin binding group. The extended half life described in that work is a property of the conjugate, not of the peptide backbone alone.
Peer reviewed pharmacokinetic characterisation of the unconjugated modified fragment in humans is sparse by comparison, and a well established half life figure for it is not specified in the accessible literature. What can be said without overstating the record is structural: lacking any albumin anchor, the free 29 residue peptide has no engineered mechanism of persistence, and its behaviour in a biological matrix is governed by ordinary peptidase activity and renal clearance of a small peptide.
How is CJC-1295 no DAC purity measured by reverse phase HPLC?
Purity is measured as the proportion of total integrated ultraviolet absorbance contributed by the main peak in a reverse phase high performance liquid chromatography separation. The sample is loaded onto a C18 bonded silica column and eluted with a gradient running from mostly aqueous to increasingly organic, typically water and acetonitrile with trifluoroacetic acid as the ion pairing additive. Peptides partition between the hydrophobic stationary phase and the mobile phase according to their surface hydrophobicity, so closely related species such as a deletion variant missing one residue, an oxidised variant or a diastereomer can separate from the parent peak and be integrated independently.
Detection is usually at 214 nanometres, where the peptide bond itself absorbs, often with a second channel at 280 nanometres, where the two tyrosine residues in this sequence absorb. The lower wavelength is the more general detector because it responds to every peptide species in the sample regardless of aromatic content, which is what makes area percent a meaningful comparison across the peaks in a chromatogram.
A purity figure means little without the method that produced it. A shallow gradient over a long run resolves impurities that a steep, fast gradient hides inside the main peak, so a credible report states the column chemistry and dimensions, the mobile phase composition, the gradient profile, the flow rate, the column temperature, the detection wavelength and the retention time of the main peak. The chromatogram image matters as much as the number, because it shows peak symmetry, baseline quality and whether integration boundaries were drawn in a way that excluded shoulders. Area percent is also a relative measure within the peptide fraction: it says nothing about water, counter-ion or inorganic salt content, which are reported separately.
What does mass spectrometry confirm that chromatography cannot?
Chromatography establishes how many species are present and in what relative proportion; mass spectrometry establishes what they are. Electrospray ionisation generates multiply protonated ions from a peptide of this size, producing a charge state envelope that is deconvoluted to a single neutral mass. That measured mass is compared against the mass calculated from the written sequence with the carboxyl terminal amide, and agreement within the tolerance of the instrument is the primary evidence that the molecule synthesised is the molecule intended.
Identity confirmation by mass is not a measure of quantity or of purity. A sample can give a clean, correct molecular ion and still contain substantial co-eluting impurity, because ionisation efficiency differs between species and the spectrum is not quantitative. The two methods are complementary, and liquid chromatography coupled to mass spectrometry links them directly by assigning a mass to each chromatographic peak, so a side peak can be identified as a deletion sequence, an oxidation product or an unrelated contaminant rather than simply counted.
Common mass relationships are informative for this particular sequence. Oxidation adds a single oxygen atom to a susceptible side chain and shifts the measured mass upward accordingly, though the substitution of leucine for methionine at position 27 removes the most oxidation prone residue from the chain. Deamidation converts an amide side chain to a carboxylic acid, a shift of roughly one mass unit that is resolvable on instruments with adequate resolution, and the substitution of glutamine for asparagine at position 8 reduces that liability relative to the native fragment. A deletion variant differs from the parent by the residue mass of whichever amino acid failed to couple, which is why residue level mass differences are the first thing examined in an impurity profile.
Which impurities arise during solid phase synthesis of this sequence?
The impurity profile of a 29 residue peptide made by solid phase synthesis is dominated by sequence related species rather than by foreign contaminants. Each residue is added in a coupling step that is efficient but never perfectly complete, so a small fraction of chains fail to extend at each cycle. Capping converts those failures into truncated chains that stop growing, while uncapped failures continue and become deletion sequences missing one internal residue. Both classes carry nearly the full sequence and can elute close to the parent peak, which is why gradient resolution is the limiting factor in detecting them.
This sequence carries two aspartic acid residues, at positions 3 and 25, each followed by a small residue. Aspartic acid followed by a small neighbour is the classic setting for aspartimide formation during repeated base treatment, producing a cyclic intermediate that can open to the alpha or beta linked product and generate closely related isomers. Racemisation at activated residues is another recognised route to diastereomeric impurity, and it has particular relevance here because position 2 is deliberately a D amino acid: the stereochemical integrity of that single residue is central to the design rationale, and epimers at that position may be difficult to resolve chromatographically.
Cleavage from the resin with strong acid in the presence of scavengers removes side chain protecting groups, and incomplete removal leaves modified chains that are detectable by mass. Purification by preparative reverse phase chromatography with trifluoroacetic acid leaves that acid associated with the basic side chains of the peptide, which is why counter-ion identity is reported separately from chromatographic purity. The practical conclusion is that an impurity table with assigned masses tells a more complete story than a single figure.
What belongs on a CJC-1295 no DAC certificate of analysis?
A complete certificate of analysis identifies the material, identifies the batch and reports the tests performed with the methods that produced them. The identification block carries the product name and synonyms, the full amino acid sequence, the molecular formula, the calculated and observed masses, the registry number where one is assigned, the physical description of the material and the net quantity stated on the label.
The batch block carries the lot number, the manufacture date, the analysis date and, where applicable, a retest date. Without a lot number the document is a specification sheet rather than a certificate, because it cannot be tied to the specific material in a specific vial.
The analytical block reports chromatographic purity with the full HPLC method and an attached chromatogram, mass spectrometric identity with the spectrum or the deconvoluted mass, water content by Karl Fischer titration, counter-ion identity and content, and net peptide content where it has been determined by amino acid analysis or nitrogen determination. Residual solvent testing and endotoxin testing appear where the intended research application calls for them, and the certificate states plainly which tests were not performed rather than leaving them implied.
The final block carries the storage statement for the lyophilized solid, the research use only statement and the identity of the laboratory that performed the testing, with a date and an authorising signature. Independent third party testing means the analysis was performed by a laboratory separate from the manufacturer, which removes the circularity of a producer certifying its own output. Real Peptides publishes those third party documents for each batch so that they can be read before procurement, and they are collected at /coas/.
How is a lot number on a research vial matched to its test report?
A lot number is printed on the vial label and repeated on the certificate of analysis, and matching the two is the whole of lot traceability from the receiving laboratory's side. The check is mechanical: the compound name on the label matches the name on the certificate, the lot string matches character for character, the analysis date precedes the shipping date, and the net quantity on the label matches the quantity described in the document.
Several failure patterns are worth recognising. A certificate with no lot field cannot be matched to anything. A certificate whose lot field is filled in by hand after the fact carries less weight than one issued by the testing laboratory with the lot embedded in the report header. A certificate for a different compound in the same family, for instance the albumin binding conjugate supplied against an order for the unconjugated fragment, will show a mass that does not correspond to the 29 residue chain, which is why reading the mass spectrometry section rather than only the purity line is worthwhile.
Documentation also supports internal record keeping. Laboratories that log the lot number against each experiment can revisit anomalous results later and establish whether a shift in response coincided with a change of batch, which is impossible when material is tracked only by compound name. Where a published method is being reproduced, recording the batch alongside the method keeps the chain of evidence intact. Catalog listings and the documents associated with them are reachable from the main catalog at /shop/, and facility and location details are published at /location/.
Why is net peptide content different from chromatographic purity?
Chromatographic purity and net peptide content answer two different questions, and a vial can score well on one and poorly on the other. Purity describes composition within the peptide fraction: of all the peptide related material detected by ultraviolet absorbance, what proportion is the target sequence. Net peptide content describes how much of the mass in the vial is peptide at all, as distinct from counter-ions, bound water, residual salts and any bulking agent.
A lyophilized peptide is not a bare molecule. Basic side chains, and this sequence has several arginine and lysine residues, associate with counter-ions carried over from purification, most often trifluoroacetate or acetate. The freeze dried solid also retains water, and it is hygroscopic enough to take up more from the atmosphere once opened. The gross mass weighed into a vial therefore exceeds the mass of peptide in it, and the difference is not trivial for a highly basic sequence.
Net peptide content is determined by amino acid analysis, in which the peptide is hydrolysed and the released amino acids are quantified against standards, or by nitrogen determination. The resulting figure allows the mass of actual peptide in a container to be distinguished from the mass of the solid. Where concentration arithmetic is recorded in a laboratory notebook, it follows from the mass stated on the label and the volume of solvent recorded: a vial containing 10 mg taken into 10 mL gives a nominal 1 mg/mL, and the same vial taken into 5 mL gives a nominal 2 mg/mL. Whether that nominal figure corresponds to peptide mass or to total solid mass depends on which of the two quantities the label reports, which the certificate should make explicit.
What does a lyophilized CJC-1295 no DAC research vial contain?
A research vial contains the peptide as a freeze dried cake or an amorphous powder, sealed under reduced pressure or under an inert headspace, in a glass vial closed with an elastomeric stopper and an aluminium seal. The visible appearance is usually described on the certificate, typically as a white to off white solid, because a discoloured or collapsed cake is an early sign that the material experienced moisture ingress or thermal stress.
Alongside the peptide, the solid contains the counter-ion from purification and residual water quantified by Karl Fischer titration. Some lyophilization cycles include a bulking agent such as mannitol to produce a mechanically robust cake, particularly where the quantity of peptide per vial is small; where such an excipient is present it should be named on the certificate, since its mass contributes to the weighed solid and would otherwise distort any calculation based on vial contents.
Vial formats for research peptides are expressed as milligrams of material per vial, and the formats available for a given compound are stated on its catalog listing rather than being fixed across the industry. The listing for this compound, with its documentation, is at CJC-1295 No-DAC. Compounds supplied in other physical formats, including materials prepared for oral research applications, are grouped at /collections/oral-research-compounds/.
One point of caution applies to any peptide label: the stated quantity is a fill specification rather than an assayed value unless the certificate records net peptide content for that lot. Where a laboratory needs the peptide mass rather than the solid mass, the amino acid analysis figure is the one to read.
How is the lyophilized powder handled and stored in a laboratory?
Lyophilized peptide is handled as a cold chain solid. Freeze dried material is substantially more stable than the same molecule in solution because the degradation routes that matter most, hydrolysis of the backbone, deamidation of amide side chains and aspartimide formation, all require water and molecular mobility. Removing water removes most of that mobility, which is why peptides are shipped and stored as solids rather than as liquids.
Laboratory handling of such a solid centres on temperature, moisture and light. Cold storage in a sealed container with desiccant is the standard arrangement, with the vial protected from light and kept closed until the material is required. Because the cake is hygroscopic, condensation on a cold vial opened in a warm room is a recognised source of moisture ingress, and laboratories typically allow sealed vials to equilibrate before the seal is broken. Repeated temperature excursions are the stress that matters most for a solid: freeze-thaw cycling is a recognised physical stress, and the literature consistently reports that repeated cycles are more damaging than a single freezing event.
The analytical record supports the handling. Water content on the certificate establishes the starting moisture state of the batch, and a retest or reanalysis of a retained sample is how a laboratory establishes whether stored material still meets the original specification rather than assuming it does. Real Peptides does not provide preparation or use guidance for any catalog compound, because these are research use only materials supplied for laboratory investigation; what the documentation does provide is the storage statement issued with the batch and the analytical baseline against which any later check is made.
How is the peptide applied in laboratory research models?
Growth hormone releasing hormone analogs are studied through a small and well defined set of experimental systems, and the modified fragment fits into the same set. At the molecular level, receptor binding experiments using membranes or cells expressing the growth hormone releasing hormone receptor measure affinity and competition against reference ligands. At the cellular level, cyclic AMP accumulation assays report the proximal consequence of Gs coupling, and reporter constructs driven by cyclic AMP response elements extend that readout to transcriptional activation.
Primary pituitary cell culture and somatotroph cell lines provide the next level, where growth hormone released into the culture medium is quantified by immunoassay and compared against unstimulated controls and against the native hormone. Because somatostatin opposes the pathway at the same cell, culture systems are often designed to control for inhibitory tone, and the magnitude of a measured response depends on that design as much as on the ligand itself.
In whole animal models, circulating growth hormone and insulin like growth factor I are the standard endpoints, with sampling frequent enough to distinguish a change in pulse amplitude from a change in baseline. Analytical work supporting those experiments relies on the same instrumentation used to characterise the material: liquid chromatography coupled to mass spectrometry is the general method for detecting and quantifying peptide analogs in biological matrices, including in anti-doping laboratories, where differentiating a synthetic analog from the endogenous hormone depends on the sequence differences that the substitutions introduce.
Across all of these systems, reproducibility rests on knowing what was in the vial. A documented lot, a measured mass, an integrated chromatogram and a stated net peptide content are what allow a result obtained with one batch to be compared with a result obtained with another.
What should be verified when evaluating a CJC-1295 no DAC supplier?
The verifiable attributes are documentation, identity and terms of supply, and all three can be checked before an order is placed. Documentation means a lot specific certificate of analysis that is available for reading rather than promised on request, that names the testing laboratory, that prints the method conditions behind each result and that attaches the chromatogram and the mass spectrum rather than only their conclusions. Independent third party testing means the analysis came from a laboratory other than the one that made the material.
Identity means that the sequence, the molecular formula and the observed mass on the certificate correspond to the unconjugated 29 residue fragment and not to the albumin binding conjugate or to the unmodified parent fragment, and that any registry number quoted matches the molecule described. Those checks take minutes and they catch the most consequential sourcing error in this particular compound family, which is the substitution of one CJC-1295 variant for the other.
Terms of supply means an explicit research use only statement, clear labelling, and shipping and storage arrangements appropriate to a cold chain solid. Supporting information such as facility location is published at /location/, and the full catalog with the documentation attached to each listing is at /shop/.
What cannot be verified from a listing is also worth naming honestly. A certificate describes the batch that was tested; it is evidence about that batch and not a guarantee about future production. Retained sample testing, consistent lot indexing and the publication of documents for every batch rather than for selected ones are the features that turn a single certificate into an ongoing record.
What is the regulatory status of CJC-1295 without DAC?
The modified fragment is not an approved medicine. It has no marketing authorisation as a drug product, it is not the subject of an approved labelling, and it is supplied and purchased as a research chemical for laboratory investigation. The published clinical work under the CJC-1295 name concerns the albumin binding construct in an investigational setting and did not result in an approved product, and the unconjugated fragment has a thinner published human record still.
In sport, growth hormone releasing factors and their analogs fall within the hormone and metabolic modulator section of the World Anti-Doping Agency Prohibited List, which covers growth hormone, its fragments and its releasing factors. That classification is why analytical methods for detecting GHRH analogs in biological matrices are an active area of anti-doping laboratory work, and it is a factual matter of listing rather than a statement about any individual circumstance.
Import and possession rules for research chemicals vary by jurisdiction and change over time, and a research organisation ordering internationally handles customs documentation according to the rules applying to it. Labelling for research use only is not a loophole; it is a statement of what the material is and of the only context in which it is supplied.
The practical consequence for a laboratory is that procurement documentation and analytical documentation serve the same purpose. A lot certificate establishes what the material is; the research use terms establish what it is for. Keeping both with the inventory record is ordinary good practice for any investigational compound held in a laboratory.
All compounds discussed on this page are sold for laboratory research use only and are not for human consumption.
References
- Prolonged stimulation of growth hormone (GH) and insulin-like growth factor I secretion by CJC-1295, a long-acting analog of GH-releasing hormone, in healthy adults. The Journal of Clinical Endocrinology and Metabolism. 2006. PMID: 16352683. pubmed.ncbi.nlm.nih.gov/16352683
Build a pack
Researching more than one compound?
Build a multi-vial pack and the discount applies automatically as you add vials.
Questions
RESEARCH USE ONLY · NOT EVALUATED BY THE FDA