Research brief
Does Semaglutide Expire? Storage and Shelf Life Explained
Short answer
Yes, semaglutide does expire, and the honest version of that answer is that it degrades continuously rather than failing on a date. Semaglutide is a 31-residue analogue of glucagon-like peptide-1 carrying a long-chain fatty diacid side group, and like every peptide it is subject to slow chemical change in the presence of water, heat, oxygen, light and mechanical stress.
Yes, semaglutide does expire, and the honest version of that answer is that it degrades continuously rather than failing on a date. Semaglutide is a 31-residue analogue of glucagon-like peptide-1 carrying a long-chain fatty diacid side group, and like every peptide it is subject to slow chemical change in the presence of water, heat, oxygen, light and mechanical stress. A printed expiry or retest date is a formalized prediction drawn from stability studies run under one defined set of storage conditions, not a switch that flips at midnight. For a laboratory, the operative questions are how much intact peptide remains, which degradation products have accumulated, and whether the material has actually been held within the conditions that its stability data describe. Material stored cold, dry, sealed and dark changes slowly. Material left warm in aqueous solution changes much faster, and the label date stops being meaningful the moment the storage history departs from the one that generated it.
What does it actually mean when a peptide like semaglutide expires?
An expiry date is a statement about a specification, not about the molecule alone. In pharmaceutical stability practice, a shelf life is the interval over which a product held under stated conditions is expected to remain within its registered specification for identity, strength, quality and the limits set for degradation products. The framework is laid out in the International Council for Harmonisation guideline Q1A(R2) on stability testing of new drug substances and products, with ICH Q5C covering biotechnological and biological materials. Both documents tie any claimed shelf life to a named storage condition, a named container closure system and a stability-indicating analytical method. Change any of those and the claim no longer applies.
Research-use peptide material is usually handled through a slightly different vocabulary. Rather than a consumer-facing expiry date, a research lot often carries a recommended storage condition and a retest date, meaning the point at which the laboratory is expected to re-examine the material against its original release criteria before further use. The distinction matters because peptides rarely fail abruptly. What typically happens is a gradual rise in related substances, a gradual fall in the main peak on reversed-phase chromatography, and sometimes the appearance of aggregated species that chromatography alone will not reveal.
So semaglutide expires in the sense that every peptide does: the population of intact molecules shrinks while the population of altered molecules grows. Whether that matters for a given experiment depends on the sensitivity of the assay, the tolerance of the model system to degradants, and how far the material has travelled past its documented storage window. A certificate of analysis describes the material at release. It does not describe the material after six months on a warm bench.
Does semaglutide need to be refrigerated?
In almost all laboratory situations the answer is yes, and the physical state of the material decides how strict the requirement is. Lyophilized semaglutide, sealed and dry, is the most forgiving form and tolerates brief ambient transit, which is why freeze-dried research peptides are routinely shipped without active cooling. Once that material is received, cold storage is the default recommendation, with freezer storage used for long-term holding. Semaglutide in aqueous solution is a different matter entirely: water is both a reactant and a mobility-granting plasticizer, and solutions are held cold because that is the only practical way to slow the reactions water enables.
The United States Pharmacopeia general chapter on packaging and storage requirements defines the relevant ranges that most storage labels borrow. Cold is defined as 2 to 8 degrees Celsius, controlled room temperature is defined as 20 to 25 degrees Celsius with permitted excursions between 15 and 30 degrees Celsius, and freezer conditions are defined as a band well below zero. Approved product labeling for marketed semaglutide formulations directs cold storage at 2 to 8 degrees Celsius with protection from light and an instruction not to freeze the finished liquid formulation, which reflects the fact that a buffered, preserved aqueous product has different vulnerabilities than a dry cake.
For dry research material the convention runs the other way: the colder and drier, the better, because the degradation pathways that threaten a lyophilized powder are driven by residual moisture and temperature rather than by ice formation. The general rule a laboratory can rely on is that refrigeration is the minimum for working stocks, freezing is appropriate for long-term dry storage, and no storage condition compensates for a container that has been left open to humid air.
Why does semaglutide need to be refrigerated rather than kept at room temperature?
Refrigeration is used because every major degradation route available to a peptide is temperature dependent, and lowering the temperature lowers all of them at once. Chemical reactions such as hydrolysis of the peptide backbone, deamidation of amide-bearing side chains, isomerization at aspartate residues and oxidation of aromatic residues all proceed through transition states whose crossing frequency rises steeply with thermal energy. A modest rise in temperature can produce a disproportionately large rise in degradation rate, which is the entire basis of accelerated stability testing described in ICH Q1A(R2). Cold storage does not stop these reactions; it buys time by pushing them into a timescale that is long compared with the working life of the material.
Temperature also governs physical instability. Peptides with amphiphilic character, which semaglutide possesses by design because of its fatty diacid side chain, can self-associate, and the literature on glucagon-like peptide-1 analogues describes a tendency toward self-assembly and fibril formation under thermal and mechanical stress. Nucleation of ordered aggregates is strongly temperature sensitive, and warm storage combined with agitation is the classic condition for generating them. Once a sample contains aggregates, the loss is often invisible to a routine purity check and must be sought with size-based or dye-binding methods.
A third reason is biological rather than chemical. Aqueous peptide solutions without an effective preservative support microbial growth, and microbial proteases will degrade a peptide far faster than spontaneous chemistry ever could. Refrigeration suppresses growth but does not sterilize, and a cold solution that was contaminated when it was made will still be contaminated. Cold storage is therefore best understood as one control among several: sealed containers, dry conditions where possible, protection from light, minimal headspace exposure and minimal handling all contribute alongside temperature.
How long does semaglutide last in the fridge?
There is no single universal interval, and the published literature does not specify one that applies across every form and formulation. What can be said plainly is that the two physical states behave very differently. Sealed, desiccated lyophilized peptide held at 2 to 8 degrees Celsius is generally the most stable practical arrangement short of a freezer, and dry peptide material is routinely assigned storage periods measured in many months under those conditions, with longer periods assigned for frozen storage. Semaglutide held in aqueous solution at the same refrigerator temperature has a markedly shorter useful life, because the reactions that require water are now unimpeded, and solution-phase handling periods for peptide working stocks are typically described in weeks rather than years.
For the marketed, fully formulated product, the approved labeling permits storage in the 2 to 8 degree Celsius range up to the labeled expiry date, which reflects a formulation developed with buffering, tonicity agents and a preservative and supported by a full ICH stability program. That number is a property of that formulation in that container, not a property of semaglutide as a molecule, and it should not be transferred onto research material in a different container, at a different concentration, in a different buffer.
The practical answer for a laboratory is therefore conditional. The lot documentation that accompanies a given batch states the storage condition under which that batch's stability expectation was set, and that document governs. Where a laboratory needs a defensible answer for its own material, the route is an in-house stability check: hold representative samples under the intended condition, pull them at intervals, and run a stability-indicating chromatographic method against the release data. That approach replaces guesswork with lot-specific evidence, which is exactly what the ICH framework asks of any shelf-life claim.
How long does semaglutide last outside the fridge?
Outside the refrigerator, the clock runs faster, and again the form of the material decides how much faster. Dry, sealed lyophilized peptide tolerates ambient transit well, which is why shipment without cooling is standard practice for freeze-dried peptides across the research supply chain. That tolerance is a statement about short excursions on the order of a shipping transit, not a licence for indefinite bench storage. Semaglutide in aqueous solution left at room temperature is in the least favourable state available to it: water, warmth, dissolved oxygen, an air to liquid interface and, frequently, light all act at once.
The published record does not define a general out-of-refrigerator interval for research-grade semaglutide, and inventing one would be worse than admitting the gap. What the regulatory literature does provide is a method for assessing excursions. The concept of mean kinetic temperature, used in pharmaceutical storage and distribution practice, converts a varying temperature history into the single isothermal temperature that would have produced the same cumulative degradation, which is why temperature data loggers accompany controlled shipments and why a logger trace is more informative than a shipment's nominal duration. An excursion assessment asks how high, how long and how many times, and compares that history against the accelerated and stress data available for the material.
Two practical corollaries follow. First, excursions are cumulative: several short warm periods are not equivalent to no warm period. Second, visual inspection is a weak detector. A solution that has lost a meaningful fraction of its intact peptide to deamidation or isomerization will usually look exactly the same as it did before, whereas visible haze or particles indicate aggregation that is already well advanced. Where a laboratory cannot reconstruct the temperature history of a container, the conservative position is to treat the stability expectation as unverified and re-examine the material analytically.
Which chemical degradation pathways act on the semaglutide backbone?
Semaglutide is built on the glucagon-like peptide-1 sequence with an alpha-aminoisobutyric acid substitution near the N-terminus, an arginine substitution further along the chain, and a C18 fatty diacid attached through a gamma-glutamate and short ethylene glycol spacer chemistry, a design described in Discovery of the Once-Weekly Glucagon-Like Peptide-1 (GLP-1) Analogue Semaglutide in the Journal of Medicinal Chemistry in 2015. That architecture determines which chemical liabilities the molecule carries.
The general peptide degradation literature identifies a consistent set of pathways relevant to a sequence of this type. Amide-bearing side chains undergo deamidation, a hydrolysis of the side-chain amide that converts the residue into an acidic form and shifts the molecular mass by roughly one unit, with the reaction accelerated by higher pH and higher temperature. Aspartate residues can cyclize to a succinimide intermediate that reopens to a mixture of normal and isomerized products, a change that leaves the mass unaltered and can only be detected by a chromatographic method capable of resolving the isomers. Backbone amide hydrolysis cleaves the chain outright and is favoured at extremes of pH. Aromatic residues, tryptophan in particular, are susceptible to oxidation that adds oxygen atoms and is promoted by trace transition metals, peroxide impurities in excipients and exposure to light. Racemization at susceptible residues is a slower background process that nevertheless matters over long storage.
The alpha-aminoisobutyric acid substitution was introduced to blunt enzymatic cleavage by dipeptidyl peptidase-4, and it does that job well, but enzymatic resistance in a biological matrix is a separate property from chemical stability in a storage container. Nothing about resistance to a protease slows deamidation or oxidation. Research describing the design of the molecule should therefore not be read as a stability claim for stored material; it explains why the peptide survives in circulation, not why it would survive on a warm shelf.
Which physical instabilities matter for semaglutide in solution?
Physical degradation changes the state of the peptide without necessarily changing its covalent structure, and it is often the pathway that ruins an experiment first. The most consequential route for a lipidated glucagon-like peptide-1 analogue is self-association. The amphiphilic character conferred by the fatty diacid side chain, which is what gives the molecule its albumin-binding behaviour, also makes it prone to forming micelle-like assemblies and, under stress, ordered fibrillar structures. The broader literature on glucagon-like peptide-1 and its analogues describes fibrillation under conditions of elevated temperature, agitation, low ionic strength or extended exposure to hydrophobic interfaces. Fibril formation is typically preceded by a lag phase, which is why a solution can appear unchanged for a period and then degrade rapidly.
Surface adsorption is the quieter problem. Peptides present at low concentration lose a disproportionate fraction of their mass to container walls, pipette surfaces and filter membranes, and the loss is concentration dependent, so a dilute working solution can read far lower than expected without any chemistry having occurred at all. Air to liquid interfaces are similarly hostile: shaking, vortexing, foaming and transport vibration expose peptide molecules to an interface that partially unfolds them and seeds aggregation.
Freezing introduces its own stresses. Ice formation concentrates solutes in the remaining liquid phase, a process known as cryoconcentration, which can push local pH and ionic strength far from their nominal values. Repeated freeze and thaw cycles are a recognized stressor in formulation science and are evaluated deliberately during stability programs for that reason. Finally, the container itself participates: closure integrity determines moisture ingress for a dry cake, and headspace composition determines oxygen exposure. A stability claim belongs to a material in a specific container, which is why ICH stability work requires the proposed container closure system to be used throughout the study.
How does the molecular design of semaglutide influence its stability profile?
Semaglutide is catalogued under CAS number 910463-68-2 and is a modified version of the native incretin sequence rather than the native peptide itself, and nearly every one of its modifications has a stability consequence. The 2015 Journal of Medicinal Chemistry report on the discovery of the molecule describes a design program aimed at extending circulating half-life through strong, reversible albumin binding, achieved by attaching a C18 diacid through a spacer to a lysine side chain, together with backbone substitutions that reduce susceptibility to enzymatic cleavage.
From a storage perspective, the fatty diacid is a double-edged feature. It raises hydrophobicity and promotes self-association, which influences solubility behaviour, adsorption to surfaces and the propensity to form higher-order structures. It also means that apparent concentration measurements can be sensitive to the association state of the material, since micelle-like assemblies behave differently in size-based separations than monomer does. The spacer chemistry linking the fatty acid to the backbone is an amide linkage rather than an ester, which is favourable, because ester linkages hydrolyse readily in aqueous media.
The substitution of alpha-aminoisobutyric acid near the N-terminus removes a classic enzymatic cleavage site and also rigidifies the local backbone. Substitution of the lysine that would otherwise be available elsewhere in the chain directs the acylation chemistry to a single site, which improves manufacturing consistency and reduces the number of positional isomers a stability method has to resolve. None of these features confers protection against deamidation, oxidation or isomerization, and a stability program must treat those pathways as live. The design literature is therefore useful for understanding why certain degradants are plausible and others are not, but it is not a substitute for direct stability data on a specific lot in a specific container.
How does temperature control the rate of degradation, and how is that used to set storage conditions?
Temperature control works because degradation chemistry follows rate laws whose constants depend exponentially on temperature, the relationship captured by the Arrhenius expression. Pharmaceutical stability programs exploit this directly: ICH Q1A(R2) prescribes long-term studies at the intended storage condition alongside accelerated studies at elevated temperature and humidity, with an intermediate condition used where the accelerated data show significant change. The accelerated arm is not a shortcut to a shelf life by itself. It provides a basis for evaluating short-term excursions and supports extrapolation only within defined limits, because different degradation pathways have different activation energies and the pathway that dominates at an elevated temperature may not be the pathway that dominates in the refrigerator.
This is the technical reason behind a common storage rule: a stability claim is inseparable from its temperature. Material whose stability has been demonstrated at 2 to 8 degrees Celsius has no demonstrated stability at 25 degrees Celsius, even though the molecule is identical. Equally, data generated at elevated temperature can overstate or understate what happens in the cold if the degradation mechanism changes across the range, which is why a stability-indicating method is expected to resolve and quantify each significant degradant rather than report a single aggregate figure.
Mean kinetic temperature extends the same logic to real distribution and storage conditions, which are never isothermal. It weights the time spent at each temperature by the degradation that temperature would cause, producing a single equivalent value that can be compared against the labeled condition. In practice this is why monitored shipping, calibrated refrigerator logging and documented excursion review are the backbone of cold chain handling. A laboratory that can show a continuous temperature record from release to use has a defensible basis for relying on the lot's stability expectation; a laboratory that cannot does not.
Why is lyophilized semaglutide more stable than semaglutide in solution?
Freeze-drying improves stability because it removes the reactant and the medium at the same time. Water participates directly in hydrolysis, deamidation and the succinimide chemistry behind aspartate isomerization, and it also acts as a plasticizer that grants molecular mobility. In a well-formed amorphous cake with low residual moisture, molecular motion is severely restricted and most degradation routes slow dramatically. This is why dry peptide material is generally assigned longer storage periods than the same peptide in aqueous solution, and why frozen dry storage is the standard arrangement for long-term holding.
The protection is conditional on several properties of the cake. Residual moisture content matters, since a small increase in water can produce a large increase in molecular mobility once the glass transition temperature of the amorphous solid falls toward the storage temperature. Cake structure matters, because collapse during processing or during a warm excursion indicates that the material has passed above its collapse temperature and that mobility has increased. Closure integrity matters, because the lyophilized state is only maintained while moisture is kept out, and peptide cakes are generally hygroscopic. Allowing a cold, sealed container to warm with the seal broken invites condensation directly onto the solid.
The freeze-drying process itself is a stress. Freezing concentrates solutes and creates ice interfaces, and drying removes the hydration shell that normally stabilizes the folded or solvated state of a peptide. Formulation scientists address this with bulking agents and stabilizers, and the presence or absence of such excipients is part of what distinguishes one lot of material from another. For this reason, stability expectations transfer poorly between a bulk peptide solid and a finished formulated product, even when the active molecule is the same.
How do pH, buffer composition and excipients govern shelf life?
Solution-phase peptide stability is strongly pH dependent, and most degradation routes have characteristic pH-rate profiles. Deamidation accelerates as pH rises into the neutral to alkaline range, backbone hydrolysis becomes prominent at acidic and strongly alkaline extremes, and succinimide formation and subsequent isomerization have their own pH optima. The result is that for any given peptide there is usually a pH window of maximum stability, and that window may not coincide with the pH of maximum solubility or with physiological pH. Marketed semaglutide formulations are buffered, which is itself a stability measure: an unbuffered solution drifts, and drift carries the material out of whatever window its data were generated in.
Buffer species are not inert. Phosphate buffers can participate in catalysis of certain reactions, and buffer salts can carry trace transition metals that catalyse oxidation of aromatic residues. Peroxide impurities present in some surfactants and polymeric excipients are a known oxidative hazard in protein formulation. Chelating agents, antioxidants and surfactants are used to counter these effects, with surfactants acting principally at air to liquid and solid to liquid interfaces where interfacial aggregation initiates. Ionic strength modulates self-association for an amphiphilic peptide, so tonicity agents can have effects on aggregation behaviour independent of their osmotic role.
Preservatives add a further dimension. Phenolic preservatives, which are standard in multi-use peptide formulations, control microbial growth but can also interact with peptide conformation and influence aggregation behaviour. The overall conclusion is that stability data belong to a complete formulation, not to a molecule. Transferring a storage expectation from a finished product to a bulk research peptide in a different medium is not supported by the data that generated it, and the sensible route is a stability assessment on the material actually in hand.
Does light exposure degrade semaglutide?
Light is a recognized stressor for peptides containing aromatic residues, and semaglutide contains tryptophan, tyrosine, phenylalanine and histidine, all of which absorb in the ultraviolet range and all of which can participate in photochemical reactions. Photo-oxidation of tryptophan is the best characterized of these routes in the protein formulation literature and generates a family of oxidation products, sometimes with secondary effects on neighbouring residues through reactive oxygen species formed in situ. Visible light can also drive reactions when photosensitizing impurities are present, which is why photostability is assessed with both ultraviolet and visible exposure rather than ultraviolet alone.
The formal framework is the ICH Q1B guideline on photostability testing of new drug substances and products, which specifies confirmatory exposure conditions and requires that the material be tested both directly and in its immediate container, so that the protection offered by the packaging can be quantified. The practical outputs of such a study are the protect-from-light statements that appear on storage labels, including those on approved semaglutide product labeling, and decisions about amber glass, opaque secondary packaging or foil overwrap.
For laboratory handling, the implications are straightforward and do not require specific numbers to state. Light exposure is cumulative, so repeated brief exposures during handling add up. Exposure is more damaging in solution than in a dry solid, because photochemical products often require water and dissolved oxygen to propagate. Storage in the original light-protective container, in a closed refrigerator or freezer rather than on an illuminated bench, removes most of the risk at no cost. Where photostability data for a specific lot are not available, the literature does not provide a figure that can be substituted, and the conservative assumption is that light exposure is best minimized.
How is a shelf life or retest date established in the first place?
A shelf life is generated by a formal stability program rather than estimated. Under ICH Q1A(R2), primary batches are placed on study in the proposed container closure system and tested at defined intervals under long-term conditions, with accelerated conditions run in parallel and an intermediate condition added if the accelerated arm shows significant change. ICH Q5C adds requirements specific to biological and biotechnological products, including an emphasis on potency assays and on methods able to detect aggregation and fragmentation. Across both documents, the central requirement is a stability-indicating analytical method: a separation capable of resolving the intact molecule from each degradation product likely to form, validated for that purpose.
Forced degradation, sometimes called stress testing, supports that method. Samples are deliberately exposed to acid, base, oxidant, heat and light so that the degradation products the method must detect can be generated and characterized. The results also indicate which pathways dominate and therefore which storage controls matter most. Forced degradation is not intended to predict real shelf life; its purpose is to prove the method sees what it needs to see.
Statistical treatment of the long-term data, including an evaluation of batch-to-batch variability, supports the proposed shelf life, and extrapolation beyond the observed data is permitted only within limits set by the guideline. Research-use material is typically assigned a conservative retest date under a stated storage condition, reflecting the general behaviour of lyophilized peptides rather than a full registration-grade program on each lot. This is why lot documentation and a willingness to re-examine stored material matter more in a research setting than the presence of a date alone. Real Peptides publishes independent third-party certificates of analysis for every batch at /coas/, which gives a laboratory the release-time analytical baseline that any later stability check is compared against.
How can a laboratory detect that stored semaglutide has degraded?
Detection requires orthogonal methods, because no single technique sees every degradation route. Reversed-phase high performance liquid chromatography is the workhorse for covalent chemical change: deamidation, oxidation and isomerization usually shift retention time, and a validated gradient can resolve related substances from the main peak. Isomerization is the case that most often escapes detection, since the isomerized species has the same mass as the parent and is distinguishable only by separation, so a method that has not been challenged with stressed samples may be blind to it.
Mass spectrometry adds identity confirmation. Deamidation produces a small mass increase, oxidation produces characteristic additions corresponding to added oxygen atoms, and hydrolytic cleavage produces fragments whose masses map onto specific positions in the sequence. Coupling the separation to a mass detector allows each new chromatographic peak to be assigned rather than merely counted.
Aggregation requires a different approach. Size exclusion chromatography detects soluble higher-order species, while light obscuration, dynamic light scattering and simple visual inspection against light and dark backgrounds address larger particles. Dye-binding fluorescence assays such as thioflavin T are used in the aggregation literature to follow fibril formation specifically, and circular dichroism reports on secondary structure changes that accompany it. A combination of a separation method, a size-based method and a functional readout is the standard way to convert a vague suspicion that material has aged into a documented finding.
What should a laboratory verify at receipt and record during storage?
Verification starts with identity. Confirming the CAS number and the molecular identity of the compound against the documentation supplied with the lot is the baseline check before any material enters a stability record, and it is the step that prevents a storage program from being built around an unverified assumption. The certificate of analysis for the lot provides the release-time characterization, and Real Peptides publishes independent third-party certificates of analysis for every batch at /coas/. Shipping origin and logistics information is available at /location/, which matters for reconstructing transit conditions when an excursion has to be assessed.
From there, the record should capture the things a stability claim depends on: the condition the material was stored under, the container it was stored in, whether the container was opened and how often, and the temperature history of the storage unit. Calibrated monitoring with alarms is the standard arrangement for refrigerated and frozen storage, and a continuous log is the only way to demonstrate that a labeled condition was actually maintained. Repeated freeze and thaw cycles are a recognized stressor and should be logged as events rather than treated as neutral handling. Visual condition of a lyophilized cake at each opening is also worth recording, since collapse or discoloration signals a change in state.
On preparation, the position is simple and fixed: Real Peptides does not provide preparation or use guidance, because these are research-use-only compounds and such guidance belongs to the investigator's own validated protocol. The framework that can be described is purely arithmetic. Concentration is mass of peptide divided by volume of solvent, expressed in milligrams per millilitre, and that relationship is what allows a stated quantity on a certificate of analysis to be converted into a working concentration within a laboratory's own method. Nothing beyond that framework is supplied here.
What are the limits of the published evidence on semaglutide stability?
The honest summary is that the public, peer-reviewed record on semaglutide stability is thin relative to the volume of literature on the molecule's pharmacology. Most of the detailed stability work supporting the marketed formulations sits in regulatory dossiers and is not published as primary literature, so the figures that appear on approved labeling are the visible output of data that cannot be independently inspected. The design literature, including the 2015 Journal of Medicinal Chemistry account of the molecule's discovery, explains the structural features that shape its behaviour but was not written as a stability study and should not be cited as one.
A second limitation is transferability. Much of what can be said about degradation pathways for this peptide is inferred from the general chemistry of peptides with the same residue types and from the broader literature on glucagon-like peptide-1 analogues. Inference of that kind identifies plausible pathways reliably, but it does not predict rates, and rates are what a shelf life is made of. A laboratory that needs a rate needs its own data.
A third limitation is lot and formulation specificity. Residual moisture, cake structure, container closure, headspace, excipients and even fill volume influence stability, so two lots of nominally identical material can behave differently under the same storage condition. This is why the guidelines insist that stability claims be tied to a defined container closure system and why any figure quoted for one presentation should not be carried across to another.
The practical consequence is a conservative posture: store cold, store dry, store dark, keep the container sealed, log the temperature, and verify analytically rather than assume. Where a specific number is wanted and the literature does not supply one, the correct answer is that the literature does not supply one.
All compounds discussed on this page are sold for laboratory research use only and are not for human consumption.
References
- Discovery of the Once-Weekly Glucagon-Like Peptide-1 (GLP-1) Analogue Semaglutide. Journal of Medicinal Chemistry. 2015. PMID: 26308095. pubmed.ncbi.nlm.nih.gov/26308095
- International Council for Harmonisation. ICH Q1A(R2): Stability Testing of New Drug Substances and Products. 2003.
- International Council for Harmonisation. ICH Q1B: Photostability Testing of New Drug Substances and Products. 1996.
- International Council for Harmonisation. ICH Q5C: Stability Testing of Biotechnological/Biological Products. 1995.
- United States Pharmacopeia. General Chapter 659: Packaging and Storage Requirements.
- US Food and Drug Administration. Approved semaglutide product labeling, Storage and Handling section.
Questions
RESEARCH USE ONLY · NOT EVALUATED BY THE FDA