Research brief
Peptide Hydrophobicity Score: Scales and Interpretation
Short answer
A peptide hydrophobicity score is a number, or a profile of numbers along a sequence, produced by assigning every residue a value from a published hydrophobicity scale and then summing, averaging or sliding a window across those values. The most widely used single value is GRAVY, the grand average of hydropathy, which is simply the mean Kyte-Doolittle hydropathy index across…
A peptide hydrophobicity score is a number, or a profile of numbers along a sequence, produced by assigning every residue a value from a published hydrophobicity scale and then summing, averaging or sliding a window across those values. The most widely used single value is GRAVY, the grand average of hydropathy, which is simply the mean Kyte-Doolittle hydropathy index across all residues in the chain. The most widely used profile is the Kyte-Doolittle hydropathy plot. A score of this kind is never interpretable on its own: it only means something when the scale, the sign convention and the window length are stated with it, because different scales were built from different model systems and some report positive values for hydrophobic residues while others report positive values for hydrophilic ones.
What is a peptide hydrophobicity score?
A peptide hydrophobicity score is a physicochemical descriptor that estimates how strongly a sequence prefers a nonpolar environment over water. The calculation is mechanical. Each of the twenty standard residues carries a value in the chosen scale, the sequence is hydrophobicity scored by adding or averaging those values, and the result is reported either as one composite figure for the whole peptide or as a trace plotted against residue number.
The units depend entirely on the scale. Some scales report free energies of transfer in kilocalories per mole, measured by partitioning model compounds or model peptides between water and a nonpolar phase. Others report unitless indices derived from how often a residue is buried in the interior of solved protein structures. Others again report chromatographic retention coefficients, which describe how strongly a residue contributes to binding on a reversed-phase column. These three families answer related but distinct physical questions, so their numbers are not interchangeable.
Sign conventions also differ and are a frequent source of misreading. On the Kyte-Doolittle hydropathy index, positive values mark hydrophobic residues and the most negative values mark charged residues such as arginine. On hydrophilicity scales built for surface and antigenic region prediction, the convention is inverted and positive peaks mark polar, solvent-exposed stretches. A score of plus one means opposite things on those two scales.
It is also worth stating what the score is not. A hydrophobicity value is not a measure of potency, stability, receptor affinity or biological function. It is a sequence-derived descriptor used for triage: flagging candidate membrane-spanning segments, locating likely surface-exposed regions, anticipating behaviour on a reversed-phase column, and contributing one term to aggregation-propensity models. Every one of those applications has published limits, and the sections below set out what the named studies actually report.
How is the Kyte-Doolittle scale calculated and what does the window do?
The Kyte-Doolittle scale combines two kinds of evidence into one hydropathy index per residue, then smooths that index along the sequence with a moving average. The method was set out in A simple method for displaying the hydropathic character of a protein in the Journal of Molecular Biology in 1982. The published index runs from strongly hydrophobic values for isoleucine and valine down to strongly hydrophilic values for arginine and lysine, with the extremes of the scale set at plus and minus four and a half. The values were assembled from water to vapour transfer energies for the side chains together with the observed tendency of each residue to sit in the interior or on the surface of solved structures, so the scale is part experimental and part statistical in origin.
The window is the part researchers most often get wrong. A hydropathy plot does not show raw per-residue values; it shows the mean of the values inside a window of fixed length, with the window advanced one residue at a time and the mean assigned to the central position. The window length sets what the plot can see. Long windows, on the order of nineteen residues, were described as appropriate for searching for membrane-spanning stretches, because a transmembrane helix needs roughly that many residues to cross a bilayer. Short windows, on the order of seven to eleven residues, were described as better suited to picking out surface-exposed polar regions, because they are not smoothed enough to erase short hydrophilic loops.
For short research peptides, the window becomes a practical obstacle. A nineteen-residue window cannot be applied meaningfully to a sequence of twelve residues, and even a nine-residue window leaves only a handful of plotted points. In that situation the profile collapses toward the composite average, which is why short peptides are more often summarised with a single composite figure than with a plot. The scale was also derived from globular and membrane proteins, not from free short peptides, so its transfer to small sequences is an extrapolation rather than a validated application.
What does a GRAVY score mean and how is it interpreted?
GRAVY, the grand average of hydropathy, is the sum of the Kyte-Doolittle hydropathy values of every residue divided by the number of residues. Nothing else enters the calculation. A positive GRAVY indicates that, on composition alone, hydrophobic residues outweigh hydrophilic ones; a negative GRAVY indicates the reverse. Values for ordinary soluble sequences typically fall below zero, while sequences dominated by aliphatic and aromatic residues move above it. Because the underlying index is bounded at plus and minus four and a half, GRAVY for a real sequence is bounded by the same limits, and in practice sits well inside them.
The interpretive caution is that GRAVY is a composition statistic, not a structural one. It is invariant to sequence order. A peptide with its hydrophobic residues clustered into one contiguous block and a scrambled version of the same peptide with those residues dispersed return the identical value, even though their partitioning, self-association and chromatographic behaviour can differ substantially. This is precisely the information that a windowed hydropathy profile preserves and that a single composite number discards.
GRAVY also ignores charge state and therefore ignores pH. The hydropathy index assigns fixed values to aspartate, glutamate, lysine, arginine and histidine, but the actual polarity of those side chains depends on protonation, which depends on the solution. Two sequences with the same composite value can behave very differently when the net charge at a given pH differs. For that reason the literature on sequence triage pairs hydrophobicity with net charge and isoelectric point rather than using either alone.
Finally, GRAVY is defined only for the twenty standard residues. Terminal amidation or acetylation, a fatty acid chain, a D-amino acid substitution, a cyclisation bridge, a non-natural residue or a polyethylene glycol group carries no hydropathy value at all. Modified research peptides are extremely common, and for those sequences a composite value calculated from the unmodified backbone composition describes a molecule that is not the one in the vial.
Why do published hydrophobicity scales disagree with each other?
Scales disagree because each one measures a different physical transfer, in a different reference system, with a different treatment of the peptide backbone. There are dozens of published scales, and a survey of the field, 50 years of amino acid hydrophobicity scales: revisiting the capacity for peptide classification in Biological Research in 2016, reported that the available scales fall into families that correlate strongly within a family and much less strongly across families, and that classification performance depends on which family is chosen for the task.
The sources of divergence are concrete. A scale built on transfer from water to octanol reports different relative values than one built on transfer from water to cyclohexane, because octanol is wet and can hydrogen bond while cyclohexane cannot. A scale built on transfer from water into the headgroup region of a lipid bilayer reports different values again, because that region is chemically heterogeneous. A scale built from burial frequencies in crystal structures measures the statistical outcome of folding under many competing constraints, not a single thermodynamic transfer. A scale built from reversed-phase retention measures interaction with an alkyl-bonded stationary phase under an organic gradient.
Purpose also drives divergence. Prediction of protein antigenic determinants from amino acid sequences, published in the Proceedings of the National Academy of Sciences in 1981, used a hydrophilicity scale with an inverted sign convention and a short averaging window, because the stated goal was locating the most solvent-exposed points in a protein rather than locating buried cores. That paper reported that the point of maximum hydrophilicity frequently fell within or close to an antigenic determinant in the proteins examined. A scale designed to find polar surface maxima is not the right instrument for scoring membrane insertion, and the reverse is equally true.
The practical consequence is that cross-study comparison of composite values is only valid within one scale. Reporting a hydrophobicity figure without naming the scale is the single most common error in this area, and it makes the number unusable by anyone else.
Which hydrophobicity scales come from experiments and which from statistics?
Both kinds exist, and they answer different questions. Statistical scales are derived from solved protein structures by measuring how often each residue type is buried away from solvent. They are inexpensive to compute, cover all twenty residues uniformly, and capture the net result of real folding, but they confound hydrophobicity with every other force that determines burial, including packing, electrostatics and chain connectivity.
Experimental and semi-empirical scales measure a defined transfer. Identifying nonpolar transbilayer helices in amino acid sequences of membrane proteins, in the Annual Review of Biophysics and Biophysical Chemistry in 1986, set out a semi-empirical scale calculated as the free energy of transferring a twenty-residue helix from water into a lipid bilayer, with each position varied in turn. That framing made the scale explicitly about helical membrane insertion rather than about isolated side chains, and it produced a numerical criterion that could be applied to a windowed profile.
A fully experimental bilayer-folding scale was reported in Side-chain hydrophobicity scale derived from transmembrane protein folding into lipid bilayers, published in the Proceedings of the National Academy of Sciences in 2011. That work used a host-guest approach in a beta-barrel outer membrane protein, substituting residues at a lipid-facing position and measuring the thermodynamics of folding into bilayers. The study reported that nonpolar and aromatic side chains contribute favourably to bilayer insertion and that the cost of burying ionisable side chains was smaller than some earlier transfer measurements in bulk solvents had suggested. Because the measurement was made in a real bilayer with a real folded protein, the scale is directly relevant to membrane contexts, although it was derived from one host protein at one position and that is a stated limit.
The general lesson from this literature is that the closer the model system is to the environment of interest, the more transferable the scale. A scale measured in bulk octanol is a weaker proxy for a bilayer than a scale measured in a bilayer, and neither is a direct proxy for the aqueous behaviour of a free short peptide.
What does the Wimley-White interfacial scale add that bulk partition scales miss?
The interfacial scale adds the backbone. Experimentally determined hydrophobicity scale for proteins at membrane interfaces, published in Nature Structural Biology in 1996, measured the partitioning of host-guest model peptides into the interfacial region of phospholipid bilayers and reported a whole-residue scale, meaning the value for each residue includes the contribution of the peptide bond and not only the side chain. The study reported that the peptide bond itself partitions very unfavourably into the interface, so unfavourably that it dominates the behaviour of short unstructured peptides.
That result reframes how a hydrophobicity score should be read. If the backbone carries a large unfavourable term, then an unstructured peptide pays that cost once per residue, and no realistic side-chain composition can overcome it for a long stretch. The way real sequences overcome it is by forming secondary structure, which satisfies backbone hydrogen bonds internally and removes much of the penalty. In other words, partitioning is coupled to folding, and a scale that counts only side chains silently assumes that coupling away.
The physical framework behind this was developed further in Membrane protein folding and stability: physical principles, in the Annual Review of Biophysics and Biomolecular Structure in 1999, which described partitioning, folding and insertion as linked steps and argued that whole-residue scales are the appropriate currency for thermodynamic reasoning about peptides at membranes. The review also distinguished interfacial partitioning, where the peptide sits in the headgroup region, from transbilayer insertion, where it crosses the hydrocarbon core, and noted that the two have different energetic requirements.
For a researcher scoring a sequence, the practical implications are that interfacial affinity and transmembrane propensity are separate predictions, that a short peptide with a modest composite value can still associate with a membrane interface if it can fold, and that any scale lacking a backbone term will understate how hard it is for an unstructured chain to leave water.
How do translocon-based scales differ from physical transfer scales?
Translocon-based scales measure what a biological insertion machine does rather than what a solvent partition does, and they report compressed values. Recognition of transmembrane helices by the endoplasmic reticulum translocon, published in Nature in 2005, used designed test segments placed in a reporter protein and read out insertion with a glycosylation-based assay in microsomes, producing an apparent free energy of membrane insertion for each segment. The follow-up study, Molecular code for transmembrane-helix recognition by the Sec61 translocon in Nature in 2007, extended the measurements across residue types and positions.
Two findings from that work matter for interpretation. First, the contribution of a residue depends strongly on where it sits within the segment: a polar or charged residue near the middle of a candidate helix is far more costly than the same residue near the ends, which a flat per-residue average cannot represent. Second, the reported apparent energies were additive to a good approximation across positions, which is what makes position-weighted scoring possible at all. The studies reported that the biological values track physical hydrophobicity in rank order but with a narrower numerical spread, so a segment that looks marginal on a bulk transfer scale may still be recognised efficiently by the insertion machinery.
A related approach is reported in An amino acid 'transmembrane tendency' scale that approaches the theoretical limit to accuracy for prediction of transmembrane helices: relationship to biological hydrophobicity, in Protein Science in 2006, which derived a scale aimed specifically at maximising transmembrane segment prediction accuracy and discussed how it relates to the biologically measured values.
The limit of translocon-based scales is that they describe co-translational insertion in one system, with designed segments rather than natural ones, and they say nothing about a synthetic peptide placed next to a model membrane in a tube. They are strong evidence about how cells select membrane segments and weaker evidence about the aqueous handling behaviour of a research peptide.
What is the hydrophobic moment and why does it matter for amphipathic peptides?
The hydrophobic moment captures how hydrophobicity is distributed around a repeating secondary structure, which a mean value cannot do. The hydrophobic moment detects periodicity in protein hydrophobicity, published in the Proceedings of the National Academy of Sciences in 1984, defined it as the vector sum of residue hydrophobicities arranged at the angular spacing of the assumed structure, which for an alpha helix is one hundred degrees per residue. A large moment means the hydrophobic residues cluster on one face of the helix; a small moment with a high mean means hydrophobicity is spread evenly, as in a transmembrane helix; a small moment with a low mean is typical of a soluble globular segment.
The study reported that plotting mean hydrophobicity against hydrophobic moment separates these classes, which is why the moment is a standard companion to the composite score rather than a competitor to it. Two sequences can be hydrophobicity scored to the same average and sit in completely different regions of that plot.
This matters for the large families of research peptides built on amphipathic helices, where one helical face is nonpolar and the opposing face is charged or polar. For such sequences, the descriptor that correlates with interfacial behaviour is the facial asymmetry, not the bulk average. The literature on amphipathic helical peptides describes a general relationship in which increasing the nonpolar face beyond a point promotes self-association in aqueous conditions and reduces selectivity between different membrane compositions, while reducing it too far weakens membrane interaction altogether, so design work in this area treats hydrophobicity as something to balance rather than maximise.
The calculation carries its own assumptions. The moment is computed for an assumed periodicity, so it presumes the peptide adopts that structure. For a sequence that is disordered in water and only folds on contact with a membrane, the moment describes a potential conformation rather than the resting one, and the magnitude depends on which underlying scale supplies the per-residue values.
How does a hydrophobicity score relate to aqueous solubility and aggregation?
The relationship is real but statistical rather than deterministic. Higher composite hydrophobicity is associated with lower aqueous solubility and a greater tendency to self-associate, because the same physical preference that drives a residue away from water also drives chains toward each other. Sequences with composite values above zero are routinely flagged as likely to be difficult to keep in aqueous solution, and sequences with long contiguous nonpolar stretches are flagged even when the whole-chain average looks unremarkable.
The quantitative literature on this is clearest for aggregation kinetics. Rationalization of the effects of mutations on peptide and protein aggregation rates, published in Nature in 2003, reported that changes in aggregation rate caused by point mutations in unstructured peptides and proteins could be rationalised by a combination of three sequence terms: the change in hydrophobicity, the change in propensity to form beta-sheet structure, and the change in net charge. Hydrophobicity was one contributor among several, not the sole determinant. The prediction method described in Prediction of sequence-dependent and mutational effects on the aggregation of peptides and proteins, in Nature Biotechnology in 2004, built a statistical mechanical model on similar physical ingredients and reported agreement with experimental aggregation behaviour across a set of peptides and proteins.
Both approaches were developed and tested on particular sequence sets under particular conditions, and neither was designed to predict the behaviour of a specific modified research peptide in a specific buffer. Ionic strength, pH relative to the isoelectric point, temperature, concentration and surface contact all influence the outcome and are absent from the sequence-derived score.
Real Peptides does not provide preparation or use guidance for any catalog compound, because these are research-use-only materials supplied for laboratory investigation. What can be stated is the concentration framework that laboratories use to describe material: concentration is label content divided by solution volume, so a vial containing 10 mg taken into 10 mL gives a nominal 1 mg/mL. That figure is arithmetic on the stated content. It is a nominal value and not a statement that the material is fully in solution, which is a physical question governed by the chemistry described above.
How do chromatographic retention scales relate to hydrophobicity scores?
Reversed-phase high performance liquid chromatography is itself a hydrophobicity measurement, and several published scales are derived from it. In reversed-phase separation, a peptide binds to a nonpolar stationary phase and is released as the organic content of the mobile phase increases, so retention time is a direct empirical readout of how strongly the molecule prefers the nonpolar surface. Retention coefficient scales assign each residue the contribution it makes to that retention, estimated from sets of model peptides, and summing those coefficients gives a predicted retention for a new sequence.
These scales behave differently from bilayer-based scales in instructive ways. The stationary phase is a uniform alkyl layer rather than a structured bilayer with a polar headgroup region, and the mobile phase contains organic solvent and an ion-pairing agent, both of which alter how charged residues contribute. The survey published as 50 years of amino acid hydrophobicity scales reported that chromatographically derived scales form a recognisable group that correlates well internally and less well with scales derived from other systems, which is consistent with the physical differences between the model environments.
Two further effects complicate the link between a composite score and observed retention. Nearest-neighbour effects mean the contribution of a residue depends on what flanks it. Conformational effects mean that a peptide able to fold into an amphipathic helix can present a preferred nonpolar face to the stationary phase and retain more strongly than its composition predicts, an effect that a purely additive composition sum cannot capture. Additive retention prediction therefore works best for short, conformationally unconstrained sequences and degrades for longer helical ones.
For laboratory purposes, the useful direction of inference is often the reverse of prediction. Observed retention behaviour on a reversed-phase method is an experimental property of the actual material, including any modifications the sequence-based score cannot see, which is one reason reversed-phase chromatography is central to the analytical documentation of peptide material rather than a sequence calculation being treated as a substitute for it.
What threshold values are used to flag a transmembrane segment?
There is no single universal cutoff, and the literature is explicit that thresholds are conventions tied to a scale and a window. The original hydropathy paper presented a display method and showed that membrane-spanning stretches appear as broad, strongly positive plateaus when a long window is used, with soluble proteins showing nothing comparable. Practice converged on a window of about nineteen residues for membrane searching, with sustained means well above zero treated as candidate segments and shorter spikes treated as noise. The semi-empirical helical transfer approach took the more explicit route of expressing the criterion as a transfer free energy for a twenty-residue helix, so that a candidate either does or does not reach a favourable transfer value.
The translocon measurements supply a different kind of boundary. Because they report an apparent free energy of insertion, the natural dividing line is the point where insertion becomes energetically favourable rather than a scale-specific index value, and the studies reported that segments near that boundary insert with intermediate efficiency rather than switching sharply.
Modern practice has largely moved past fixed thresholds on a smoothed line. Predicting transmembrane protein topology with a hidden Markov model: application to complete genomes, published in the Journal of Molecular Biology in 2001, described a probabilistic model that treats the protein as a sequence of states for membrane helix, inside loop and outside loop, and reported improved discrimination of membrane proteins and better topology assignment than threshold-based hydropathy inspection, as well as a genome-wide application. The model incorporates hydrophobicity implicitly through its emission probabilities but adds grammar, including the charge bias between the two sides of the membrane, that a simple average cannot express.
For short synthetic peptides, none of this transfers cleanly. Transmembrane thresholds were derived for segments embedded in full-length proteins with flanking sequence and a biological insertion pathway, and applying them to a free twelve-residue or twenty-residue peptide asks the criterion to answer a question it was not calibrated for.
How are hydrophobicity scores used in peptide design and sequence screening?
They are used as fast, cheap filters that rank sequences before any material exists, and as explanatory descriptors afterwards. In screening, a set of candidate sequences is scored on one named scale, and the extremes are flagged: strongly positive composites for likely aqueous handling difficulty, long nonpolar runs for aggregation risk, high hydrophobic moment at moderate mean for likely amphipathic membrane interaction, and strongly hydrophilic local maxima for likely surface exposure. Each flag points to an experiment rather than replacing one.
In analog design, the score functions as a controlled variable. When a series differs by single substitutions, the change in composite value and the change in local profile provide a physical axis along which to interpret differences in observed behaviour, and the aggregation literature cited above supports treating hydrophobicity change, beta-sheet propensity change and charge change as the relevant trio rather than hydrophobicity alone.
The practical requirements for doing this well are modest but strict. The scale must be named in any report, because a composite figure without a scale cannot be reproduced. The window length must be named for any profile. The same scale must be used throughout a comparison set. Modified positions must be identified explicitly as unscored, since terminal caps, lipid chains, non-natural residues and cyclisation bridges have no values in standard scales and the calculated figure describes only the unmodified backbone composition. Net charge and isoelectric point should be reported alongside, because the polarity of ionisable residues is a function of solution pH that the hydropathy index fixes at a single value.
It is also sound practice to score a sequence on more than one scale from different families, for example one statistical index, one bilayer-derived scale and one interfacial whole-residue scale. Where the families agree, the conclusion is robust. Where they disagree, the disagreement is informative, because it usually marks a sequence whose behaviour depends on the environment in question, and that is exactly the case where a single number would mislead.
What are the limits of any peptide hydrophobicity score?
The limits are substantial and well documented, and the honest summary is that these scores are screening descriptors, not measurements of the molecule in hand. The first limit is scale dependence. Numbers from different scales are not comparable, their sign conventions differ, and the survey literature reports that scales cluster into families whose cross-family correlation is weak. A figure reported without its scale carries no information.
The second limit is that composition is not conformation. A whole-chain average is blind to sequence order, so clustering and dispersion of nonpolar residues look identical to it, while the interfacial partitioning work shows that folding and backbone hydrogen bonding dominate whether a chain can leave water at all. The third limit is coverage: standard scales define values for twenty residues only, and a large share of research peptides carry modifications outside that set.
The fourth limit is context. Scales are measured in specific systems, octanol, cyclohexane, a lipid interface, a bilayer core, an alkyl stationary phase or a translocon, and a sequence that scores high in one context need not behave the same in another. The fifth limit is that solution variables simply are not in the calculation. pH, ionic strength, buffer composition, temperature, concentration and surface interaction all affect real behaviour and none of them appear in a sequence sum.
The sixth limit is the one most often forgotten: a hydrophobicity score says nothing about biological activity. It is a description of a sequence, not of a function, and no published scale claims otherwise. Where the literature links hydrophobicity to a functional outcome, as in the amphipathic helical peptide literature, the relationship is reported as a trend across a designed series under stated conditions, with the usual caveats about model systems and endpoints. Treating any of these values as a prediction about what a compound will do is beyond what the source studies support.
How does hydrophobicity information fit into sourcing and documentation for research peptides?
Sequence-derived hydrophobicity belongs to the planning stage; analytical documentation describes what is actually in a vial, and the two should not be confused. A composite score is calculated from a sequence a researcher types into a tool. A certificate of analysis reports measurements made on a specific lot of material, typically including identity confirmation by mass spectrometry and chromatographic analysis, and it is the document that connects a calculation to a physical sample.
Before procurement, the usual identity checks are the compound name and any canonical code, the CAS number where one exists, the molecular formula and the expected monoisotopic or average mass, and the exact modification state, since terminal amidation, acetylation or acylation changes both the mass and the physicochemical profile that any score is meant to describe. Confirming the modification state matters directly here: a sequence calculation performed on the unmodified backbone of an amidated or acylated peptide describes a different molecule from the one supplied.
Real Peptides supplies research-use-only compounds for laboratory investigation and publishes independent third-party certificates of analysis for every batch at /coas/, so the lot documentation for a catalog item can be reviewed and verified against the identity information above. Catalog compounds are listed at /shop/, and shipping and location information is published at /location/. Real Peptides does not provide preparation, handling or use guidance for any catalog compound, because these materials are supplied for laboratory research only.
The one quantitative framework appropriate to a supplier page is concentration arithmetic, which is label content divided by solution volume and nothing more. It states a nominal relationship between a stated mass and a stated volume, and it is independent of whether a given sequence is hydrophobic. Whether a hydrophobic sequence actually reaches a nominal concentration in a given aqueous system is a physical question determined by the sequence chemistry, by the modification state of the material, and by the conditions of the laboratory system in question, and it is answered experimentally rather than by a sequence calculation.
All compounds discussed on this page are sold for laboratory research use only and are not for human consumption.
References
- A simple method for displaying the hydropathic character of a protein. Journal of Molecular Biology. 1982. PMID: 7108955. pubmed.ncbi.nlm.nih.gov/7108955
- Prediction of protein antigenic determinants from amino acid sequences. Proceedings of the National Academy of Sciences. 1981. PMID: 6167991. pubmed.ncbi.nlm.nih.gov/6167991
- Experimentally determined hydrophobicity scale for proteins at membrane interfaces. Nature Structural Biology. 1996. PMID: 8836100. pubmed.ncbi.nlm.nih.gov/8836100
- Membrane protein folding and stability: physical principles. Annual Review of Biophysics and Biomolecular Structure. 1999. PMID: 10410805. pubmed.ncbi.nlm.nih.gov/10410805
- The hydrophobic moment detects periodicity in protein hydrophobicity. Proceedings of the National Academy of Sciences. 1984. PMID: 6582470. pubmed.ncbi.nlm.nih.gov/6582470
- Identifying nonpolar transbilayer helices in amino acid sequences of membrane proteins. Annual Review of Biophysics and Biophysical Chemistry. 1986. PMID: 3521657. pubmed.ncbi.nlm.nih.gov/3521657
- Recognition of transmembrane helices by the endoplasmic reticulum translocon. Nature. 2005. PMID: 15674282. pubmed.ncbi.nlm.nih.gov/15674282
- Molecular code for transmembrane-helix recognition by the Sec61 translocon. Nature. 2007. PMID: 18075582. pubmed.ncbi.nlm.nih.gov/18075582
- Side-chain hydrophobicity scale derived from transmembrane protein folding into lipid bilayers. Proceedings of the National Academy of Sciences. 2011. PMID: 21606332. pubmed.ncbi.nlm.nih.gov/21606332
- An amino acid 'transmembrane tendency' scale that approaches the theoretical limit to accuracy for prediction of transmembrane helices: relationship to biological hydrophobicity. Protein Science. 2006. PMID: 16877712. pubmed.ncbi.nlm.nih.gov/16877712
- Rationalization of the effects of mutations on peptide and protein aggregation rates. Nature. 2003. PMID: 12917692. pubmed.ncbi.nlm.nih.gov/12917692
- Prediction of sequence-dependent and mutational effects on the aggregation of peptides and proteins. Nature Biotechnology. 2004. PMID: 15361882. pubmed.ncbi.nlm.nih.gov/15361882
- Predicting transmembrane protein topology with a hidden Markov model: application to complete genomes. Journal of Molecular Biology. 2001. PMID: 11152613. pubmed.ncbi.nlm.nih.gov/11152613
- 50 years of amino acid hydrophobicity scales: revisiting the capacity for peptide classification. Biological Research. 2016. PMID: 27378087. pubmed.ncbi.nlm.nih.gov/27378087
Questions