Ships within 24 hours on business days · +10% with Bank Pay

Research brief

What Converts Angiotensin 1 to Angiotensin 2?

46 WORDS

Short answer

What converts angiotensin 1 to angiotensin 2 is angiotensin-converting enzyme, abbreviated ACE, a zinc-dependent peptidyl dipeptidase anchored to the outer surface of vascular endothelial cells. ACE removes the two C-terminal residues, histidine and leucine, from the decapeptide angiotensin I and leaves behind the octapeptide angiotensin II.

What converts angiotensin 1 to angiotensin 2 is angiotensin-converting enzyme, abbreviated ACE, a zinc-dependent peptidyl dipeptidase anchored to the outer surface of vascular endothelial cells. ACE removes the two C-terminal residues, histidine and leucine, from the decapeptide angiotensin I and leaves behind the octapeptide angiotensin II. That single hydrolysis is the entire conversion step: no rearrangement, no cofactor peptide, no second enzyme required. The reaction occurs anywhere ACE is displayed on an endothelial or epithelial surface, and it is most concentrated in the pulmonary capillary bed, where an enormous endothelial surface area meets the full output of the right heart. The paragraphs below describe the chemistry of the cleavage, the anatomy of where it happens, the enzymes that can perform the same conversion by other routes, and what the named published studies report.

Which enzyme converts angiotensin 1 to angiotensin 2?

The enzyme is angiotensin-converting enzyme, classified as a peptidyl dipeptidase (EC 3.4.15.1) and known in the older kinin literature as kininase II. ACE is a type I integral membrane glycoprotein with a large extracellular ectodomain, a single membrane-spanning segment and a short cytoplasmic tail. The somatic form expressed in endothelium, kidney and other tissues carries two homologous catalytic domains, conventionally called the N domain and the C domain, each built around a zinc-binding motif of the HEXXH type characteristic of the gluzincin metallopeptidases. A shorter germinal isoform expressed in developing male germ cells is transcribed from an alternative promoter within the same gene and carries only the C-type catalytic unit.

The duplication matters because the two domains are not interchangeable. The literature describes the C domain as the dominant site of angiotensin I hydrolysis under physiological chloride conditions, while the N domain shows relative preference for other substrates, notably the tetrapeptide Ac-SDKP. Both domains are catalytically competent on angiotensin I in purified systems, so measurements made with isolated domains do not translate directly to the behaviour of the intact two-domain enzyme on a cell surface. A membrane-bound sheddase releases a soluble ectodomain into plasma, which is the species measured by conventional plasma ACE activity assays. That circulating pool is catalytically active, but the literature consistently treats the membrane-anchored enzyme on the endothelial luminal surface as the quantitatively important converter in the intact circulation.

How does angiotensin 1 become 2 at the chemical level?

Angiotensin I is a decapeptide with the sequence Asp-Arg-Val-Tyr-Ile-His-Pro-Phe-His-Leu. ACE binds the peptide so that its free C-terminal carboxylate is held in a specificity pocket, positions the scissile bond between phenylalanine (position 8) and histidine (position 9) over the active-site zinc, and hydrolyses that bond. The dipeptide His-Leu leaves, and the remaining octapeptide Asp-Arg-Val-Tyr-Ile-His-Pro-Phe is angiotensin II. This is what turns angiotensin 1 into 2 at the level of covalent chemistry: one peptide bond broken, one dipeptide released.

The catalytic mechanism is the general-base route common to zinc metallopeptidases. The active-site zinc ion, coordinated by two histidines of the HEXXH motif and a downstream glutamate, polarises a water molecule; an adjacent glutamate acts as a general base and deprotonates that water; the resulting hydroxide attacks the carbonyl carbon of the scissile bond to give a tetrahedral intermediate that collapses with proton transfer to the leaving amine. Because the enzyme requires a free C-terminal carboxyl group and cleaves two residues back from it, substrates with a C-terminal proline at the penultimate position are resistant, which is why angiotensin II itself is not further trimmed by ACE.

Chloride anion is a well-described activator of the reaction. Chloride binding at sites remote from the zinc increases the enzyme's activity toward angiotensin I, and this chloride dependence differs between the N and C domains. Research on the structural biology of ACE describes a largely alpha-helical ectodomain with a deep, narrow channel that admits short peptides and excludes large folded proteins, which explains why ACE behaves as an oligopeptidase rather than a general protease.

Where is angiotensin 1 converted in the body?

Angiotensin I is converted wherever ACE is expressed on an accessible surface, and the enzyme is widely distributed. The highest densities described in the literature are on pulmonary capillary endothelium, on the brush border of the renal proximal tubule, on intestinal brush-border membranes, on the choroid plexus epithelium, in the epididymis and developing sperm (the germinal isoform), and on endothelium throughout the systemic vasculature. Because the catalytic domains face the lumen, plasma-borne angiotensin I meets the enzyme without needing to enter a cell.

Two compartments therefore matter. The first is the circulating compartment, where angiotensin I generated from angiotensinogen by renin is carried in plasma and converted as it passes endothelial surfaces. The second is the tissue compartment, where local renin-angiotensin components generate and convert angiotensin peptides within an organ's interstitium, close to the receptors that respond to them. Research on tissue systems describes measurable angiotensin II in heart, kidney, adrenal, brain, vasculature and adipose tissue at concentrations that are not simply explained by uptake from plasma, which supports local conversion as a real contributor.

Soluble ACE shed into plasma adds a third, smaller route. Conversion by circulating enzyme does occur, but surface-bound enzyme in a capillary bed presents far more active sites per unit of plasma volume than the dilute soluble pool, and the literature generally treats endothelial surface conversion as dominant. The practical consequence for study design is that plasma ACE activity and endothelial converting capacity are related but not identical measurements, and the two can move independently.

Is angiotensin 1 converted to 2 in the lungs?

Yes. The pulmonary vascular bed is the classical site of angiotensin I conversion, and it has been described that way since the earliest physiological work on the converting step. Three anatomical facts explain why. The entire cardiac output passes through the lung on every circuit, so all plasma meets pulmonary endothelium repeatedly. The pulmonary capillary network presents a very large endothelial surface relative to the volume of blood it contains. And ACE is expressed at high density on that endothelium, concentrated on the luminal membrane and in the caveolae and microvillous projections that face the blood.

Classical isolated perfused lung preparations established the point directly: angiotensin I entering the pulmonary artery emerges from the pulmonary vein substantially converted to angiotensin II in a single pass, and the conversion is abolished by active-site inhibitors of ACE. The same preparations showed that bradykinin is inactivated across the same bed by the same enzyme, which is how ACE and kininase II came to be recognised as one protein with two major substrates.

That said, the lung is not the only site, and framing conversion as exclusively pulmonary is an oversimplification the literature has long since corrected. Systemic endothelium, renal brush border and local tissue systems all contribute, and in experimental settings where pulmonary endothelium is injured, conversion does not stop. The accurate statement is that the lung is the largest single converting surface in the body, not that it is the only one.

Does angiotensin 1 go to the lungs, and is angiotensin 1 in the lungs?

Angiotensin I does reach the lungs, and angiotensin I is present in lung tissue and pulmonary blood. Angiotensin I generated in the systemic circulation is carried by venous return to the right heart and then into the pulmonary artery, so the lung sees it on every pass. In addition, the lung expresses its own renin-angiotensin components, and angiotensinogen-derived peptides can be generated locally within pulmonary tissue, so angiotensin I is found in the organ independently of what arrives in the blood.

The lung is therefore both a destination and a processing surface for this peptide. Angiotensin I arriving in pulmonary blood is largely stripped of its C-terminal dipeptide during transit, which is why arterial blood leaving the lung is relatively enriched in angiotensin II compared with the mixed venous blood entering it. Because angiotensin II is itself rapidly degraded by aminopeptidases and other peptidases in plasma and tissue, the measured concentrations of both peptides in any sample depend heavily on how the sample was collected and whether peptidase inhibitors were present at collection.

The pulmonary location also explains why lung biology keeps reappearing in renin-angiotensin research. The same endothelial surface that converts angiotensin I carries the related carboxypeptidase ACE2, and published work in mouse models reports that ACE2 loss worsens lung injury endpoints in several experimental insults, as described in Angiotensin-converting enzyme 2 protects from severe acute lung failure (Nature, 2005). The two enzymes sit on the same tissue and pull the angiotensin pool in opposite directions.

Where does angiotensin I come from before the conversion step?

Angiotensin I is produced one step earlier in the cascade by renin acting on angiotensinogen. Angiotensinogen is a large glycoprotein secreted mainly by the liver and circulating in plasma at concentrations well above the Michaelis constant of renin, which makes renin release the rate-limiting event for the whole system. Renin is an aspartyl protease stored in granules of the juxtaglomerular cells of the renal afferent arteriole; it is highly specific and cleaves angiotensinogen at a single site to liberate the decapeptide angiotensin I.

The classical triggers for renin release described in renal physiology are reduced perfusion pressure sensed by the afferent arteriole, reduced sodium chloride delivery sensed by the macula densa, and beta-adrenergic signalling from renal sympathetic nerves. Angiotensin II feeds back negatively on renin release, closing the loop. Prorenin, the zymogen form, circulates in larger amounts than active renin and has its own receptor-mediated biology that is still being characterised.

Angiotensin I itself is essentially a circulating precursor rather than an effector. It has little intrinsic agonist activity at the angiotensin receptors at physiological concentrations, and most of the pressor activity attributed to it in early bioassays reflected conversion to angiotensin II in the test preparation. That distinction is central to the design of modern experiments: comparing responses to infused angiotensin I against responses to angiotensin II is the standard way to estimate converting capacity in a vascular bed, because only the angiotensin I response depends on an intact converting step.

What turns angiotensin 1 into 2 inside tissues rather than in blood?

Within tissues, the same enzyme does most of the work, but it does it in a different physical setting. Tissue ACE is expressed by endothelial cells of the organ's own microvasculature, by some epithelial populations, by fibroblasts and by monocyte-derived macrophages, and the angiotensin II it generates acts over short distances on neighbouring cells rather than travelling in plasma. Research on local renin-angiotensin systems describes angiotensin peptide concentrations in heart and kidney tissue that exceed what simple equilibration with plasma would predict, and describes renin uptake from the circulation as well as local synthesis of some components.

The kidney is the best-characterised example. Proximal tubule brush-border ACE, intratubular angiotensinogen and filtered or locally produced renin together support generation of angiotensin II within the tubular lumen and interstitium at concentrations far above plasma levels. Cardiac tissue carries a comparable local system, with the added feature that mast cell proteases contribute to conversion there, as described in the next section.

An intracellular or intracrine arm has also been proposed, in which angiotensin II generated or internalised within a cell acts on nuclear or cytoplasmic targets. The evidence base for intracrine signalling is smaller and more model-dependent than for the extracellular pathways, and the published work in this area relies heavily on overexpression systems and on reagents whose specificity is debated. The cautious reading is that local extracellular conversion is well supported, while intracellular conversion remains an active and unsettled question.

What else changes angiotensin 1 to 2 besides ACE?

ACE is not the only protease capable of making angiotensin II from angiotensin I. Chymase, a chymotryptic serine protease stored in mast cell granules, cleaves the same Phe8-His9 bond and is described in the literature as a major non-ACE converting activity in human heart and in some vascular tissues. Cathepsin G, tonin, kallikrein and a chymostatin-sensitive angiotensin-generating enzyme have also been reported to generate angiotensin II from angiotensin I or directly from angiotensinogen in various preparations.

These alternative routes are the usual explanation offered for so-called ACE escape, the observation in pharmacological studies that angiotensin II concentrations can recover during sustained ACE inhibition. They are also a major source of species differences. Chymase activity and substrate specificity differ substantially between rodents and humans, so results about the relative contribution of chymase in a mouse or rat model do not transfer cleanly to human tissue, and several published comparisons make exactly that point.

The practical consequence for experimental design is that inhibitor-based attribution needs care. Showing that a converting activity is blocked by an active-site ACE inhibitor supports an ACE-mediated route; showing that residual conversion survives such an inhibitor but is blocked by chymostatin or a serine protease inhibitor supports a chymase-like route. Studies that measure only the end product without inhibitor controls cannot say which enzyme performed the cleavage, and several apparent contradictions in the older literature resolve once the inhibitor controls are compared.

What does ACE do besides converting angiotensin I?

ACE is a promiscuous oligopeptidase, and the conversion of angiotensin I is only one of its described reactions. Its second classical substrate is bradykinin, which ACE inactivates by sequential removal of C-terminal dipeptides; this activity is the reason the enzyme was independently named kininase II. Because angiotensin II is a vasoconstrictor and bradykinin a vasodilator, a single enzyme sits at the junction of two opposing vasoactive systems, and inhibition of the enzyme shifts both at once.

Other substrates reported in the literature include substance P, the haemoregulatory tetrapeptide Ac-SDKP, enkephalins, neurotensin, luteinising hormone-releasing hormone and angiotensin-(1-7). Domain selectivity shapes this list: Ac-SDKP is described as a preferred N-domain substrate, while angiotensin I and bradykinin are handled efficiently by the C domain. This has driven interest in domain-selective inhibitors as research tools, because they allow one arm of ACE biology to be probed while leaving the other comparatively intact.

ACE also has reported functions that do not depend on peptide hydrolysis, including signalling through its cytoplasmic tail after inhibitor binding and roles in immune cell biology. These are less established than the peptidase activities and rest on a narrower set of models. For the specific question of what enzyme converts angiotensin 1 to 2, the relevant point is simpler: the conversion is a C-domain-dominant dipeptidyl carboxypeptidase reaction, and the enzyme performing it is simultaneously degrading several other short peptides in the same tissue.

How is the conversion step inhibited or regulated?

The conversion step is regulated at the level of enzyme expression, enzyme shedding, chloride availability and active-site occupancy. The best-characterised intervention is competitive active-site inhibition. ACE inhibitors are small molecules designed around the enzyme's substrate groove, carrying a zinc-binding group (a sulfhydryl in captopril, a carboxylate in lisinopril and enalaprilat, a phosphinate in others) that coordinates the catalytic zinc and blocks hydrolysis of angiotensin I. This class is studied extensively in cardiovascular pharmacology, and in experimental systems these compounds abolish single-pass pulmonary conversion of angiotensin I, which is one of the standard demonstrations that ACE is the responsible enzyme.

Expression-level regulation is slower. ACE transcription in endothelial and other cells responds to inflammatory mediators, shear stress and glucocorticoids in published cell and animal work, and ectodomain shedding governs how much enzyme leaves the membrane for the soluble plasma pool. A well-described insertion/deletion polymorphism in the human ACE gene is associated with differences in circulating enzyme concentration, which is one reason plasma ACE activity varies widely between individuals in research cohorts and is a poor standalone proxy for tissue converting capacity.

Substrate supply is the other control point. Because renin release sets the rate of angiotensin I formation and angiotensinogen is normally abundant, the converting step is rarely rate-limiting in an intact system with normal ACE expression. Experiments that perturb ACE alone therefore often produce smaller changes in angiotensin II than expected, while experiments that perturb renin move the whole cascade. Any interpretation of a converting-step manipulation needs the upstream substrate flux measured alongside it.

Does ACE2 convert angiotensin 1 to angiotensin 2?

No. ACE2 is a homologue of ACE, but it is a carboxypeptidase, not a dipeptidyl carboxypeptidase, and it removes a single C-terminal residue rather than a dipeptide. Acting on angiotensin I it produces angiotensin-(1-9), not angiotensin II. Acting on angiotensin II it produces angiotensin-(1-7), which signals through a different receptor and is generally described as opposing the angiotensin II axis.

This chemistry was established in the two independent reports that identified the enzyme. A novel angiotensin-converting enzyme-related carboxypeptidase (ACE2) converts angiotensin I to angiotensin 1-9 (Circulation Research, 2000) described cloning of the enzyme from a human heart cDNA library, its carboxypeptidase activity on angiotensin I and angiotensin II, and its expression pattern. A human homolog of angiotensin-converting enzyme. Cloning and functional expression as a captopril-insensitive carboxypeptidase (Journal of Biological Chemistry, 2000) reported the same single-residue specificity and, importantly, that the enzyme was not inhibited by classical ACE inhibitors. That insensitivity is a defining practical difference: an experiment using an ACE inhibitor to block angiotensin I conversion leaves ACE2 activity running.

The two enzymes therefore act as opposing arms on the same peptide pool. ACE drives angiotensin I toward angiotensin II; ACE2 drains angiotensin I and angiotensin II toward the angiotensin-(1-9) and angiotensin-(1-7) products. Both are present on endothelium, including pulmonary endothelium, which is why mass-spectrometric profiling of several angiotensin peptides at once has become the preferred way to characterise the balance rather than measuring a single peptide.

What do the published ACE2 studies report about the lung?

The ACE2 literature is relevant to the conversion step because it describes the same tissue surface from the other direction. Angiotensin-converting enzyme 2 protects from severe acute lung failure (Nature, 2005) reported that mice lacking ACE2 showed worse lung injury endpoints across several experimental insults, that recombinant ACE2 protein improved those endpoints, and that signalling through the AT1a receptor contributed to the injury phenotype. The model is murine and the insults are acute and experimental, so the findings describe a regulatory axis rather than any clinical outcome.

A crucial role of angiotensin converting enzyme 2 (ACE2) in SARS coronavirus-induced lung injury (Nature Medicine, 2005) reported that viral spike protein engagement downregulated ACE2 and that this loss contributed to injury severity in mouse models, with angiotensin receptor blockade attenuating the effect. The receptor relationship itself was established in Angiotensin-converting enzyme 2 is a functional receptor for the SARS coronavirus (Nature, 2003), which identified ACE2 as the binding partner for the viral spike S1 domain and showed that ACE2-expressing cells supported viral replication in culture.

Taken together, this body of work supports a picture in which the pulmonary endothelial and epithelial surface carries both the enzyme that makes angiotensin II and the enzyme that disposes of it, and in which perturbing one arm shifts the local peptide balance. The limits are the usual ones: the primary evidence is from genetically modified mice, recombinant proteins and cell culture, the injury models are acute, and the angiotensin peptide measurements in these reports were made with the assay technologies available at the time.

What happens after angiotensin II is formed?

Once formed, angiotensin II acts chiefly through two G protein-coupled receptors, AT1 and AT2. AT1 signalling is responsible for most of the classically described actions: arteriolar vasoconstriction, aldosterone release from the adrenal zona glomerulosa, renal sodium retention, vasopressin release, thirst, facilitation of sympathetic transmission and a set of growth and remodelling signals in cardiac and vascular tissue. AT2 signalling is generally described in the literature as opposing several of these actions, with expression patterns that differ markedly between fetal and adult tissue.

Angiotensin II is short-lived in plasma, with a half-life described in the physiology literature as being on the order of seconds, because aminopeptidases and other peptidases act on it quickly. Aminopeptidase A removes the N-terminal aspartate to give angiotensin III, which retains substantial AT1 activity; aminopeptidase N then yields angiotensin IV, which has its own binding site. ACE2 and other carboxypeptidases generate angiotensin-(1-7), which acts largely through the Mas receptor and is generally reported to oppose AT1-mediated effects.

The practical implication for anyone measuring the system is that angiotensin II concentration in a sample is the product of formation rate and removal rate, not of formation alone. Two preparations with identical converting capacity can report different angiotensin II levels if their peptidase activity differs, and sample handling alone can change the measured value. Modern peptide-profiling approaches address this by measuring the whole panel of angiotensin metabolites under controlled conditions and reporting ratios rather than isolated concentrations.

How do laboratories study the conversion step?

The conversion step is studied with a small set of established laboratory approaches. Enzyme activity assays use synthetic substrates such as hippuryl-His-Leu or internally quenched fluorogenic peptides that release a measurable signal when ACE cleaves them; these are convenient but report activity on a surrogate rather than on angiotensin I itself. Direct substrate assays incubate angiotensin I with enzyme, cells or tissue and quantify the products by high-performance liquid chromatography or by liquid chromatography coupled to tandem mass spectrometry, which resolves angiotensin II from angiotensin-(1-9), angiotensin-(1-7) and the aminopeptidase products in a single run.

Physiological preparations add the vascular context. Isolated perfused lung and isolated vessel preparations compare the response or the product recovery for angiotensin I against angiotensin II, with and without an active-site inhibitor, which is the classical way to quantify converting capacity across a bed. Cultured endothelial cells provide a reduced system in which surface ACE can be measured and manipulated, and genetically modified mice allow the contribution of ACE, ACE2 or specific receptors to be removed and the peptide profile re-measured.

Material identity underpins all of it. Angiotensin peptides are short, their analogues differ by a single residue, and an assay cannot distinguish a mislabelled peptide from an unexpected biological result. Verifying a compound's CAS number, molecular formula and monoisotopic mass against the certificate of analysis before procurement, and checking that the certificate corresponds to the lot in hand, is standard practice in peptide laboratories for exactly this reason. Real Peptides publishes independent third-party certificates of analysis for every batch at /coas/.

What are the limits of the evidence on the conversion step?

The core chemistry is settled: a zinc metallopeptidase removes a C-terminal dipeptide from a decapeptide to give an octapeptide, and that is what changes angiotensin 1 to 2. The uncertainty sits around the quantitative questions. How much of the body's angiotensin II is formed in the pulmonary bed versus in local tissues is model-dependent and difficult to measure in an intact organism, and published estimates vary with the technique used. How much non-ACE conversion contributes in human tissue is similarly contested, with chymase evidence strong in some cardiac preparations and weak in others.

Species differences are a persistent limitation. Much of the mechanistic work rests on rodent models whose chymase biology, receptor subtype distribution and local renin-angiotensin component expression differ from human tissue. Findings from knockout mice describe what happens when an enzyme is absent from conception, which is not the same as what happens when its activity is reduced acutely in an adult animal. Cell culture isolates endothelial ACE from the shear stress, flow and cellular neighbours that regulate it in vivo.

Assay methodology is the third limitation. Peptide measurements are sensitive to collection conditions, peptidase inhibition at sampling and the specificity of the detection method, and older radioimmunoassay data may not align with modern mass-spectrometric profiles. The honest summary is that the identity of the converting enzyme and the mechanism of the cleavage are well established, while the apportionment of conversion between compartments and between enzymes remains a live research question.

How does Real Peptides fit into renin-angiotensin research?

Real Peptides supplies research-use-only peptides to researchers and laboratories, with the catalog listed at /shop/ and independent third-party certificates of analysis published for every batch at /coas/. Shipping and location information is available at /location/. Real Peptides does not provide preparation or use guidance for any catalog compound, because these are research-use-only materials supplied for laboratory investigation.

For work on the renin-angiotensin cascade, documentation matters as much as the material. A certificate of analysis that reports identity by mass spectrometry and chromatographic profile allows a laboratory to confirm that the peptide in the vial is the sequence named on the label before it enters an enzyme assay, a cell experiment or an analytical standard curve. Where concentration needs to be described, the arithmetic is straightforward at the container level: a vial containing 10 mg taken into 10 mL gives a nominal 1 mg/mL, and that nominal figure is a property of the container, not a statement about how any material is handled.

The broader point for this topic is that the converting step is defined by a specific enzyme acting on a specific sequence. Research that depends on that specificity depends in turn on knowing exactly which molecule is in the tube, which is why molecular identity verification against publicly available lot documentation is treated as a procurement step rather than an afterthought in peptide laboratories.

All compounds discussed on this page are sold for laboratory research use only and are not for human consumption.

References

  • A novel angiotensin-converting enzyme-related carboxypeptidase (ACE2) converts angiotensin I to angiotensin 1-9. Circulation Research. 2000. PMID: 10969042
  • A human homolog of angiotensin-converting enzyme. Cloning and functional expression as a captopril-insensitive carboxypeptidase. Journal of Biological Chemistry. 2000. PMID: 10924499
  • Angiotensin-converting enzyme 2 is a functional receptor for the SARS coronavirus. Nature. 2003. PMID: 14647384
  • Angiotensin-converting enzyme 2 protects from severe acute lung failure. Nature. 2005. PMID: 16001071
  • A crucial role of angiotensin converting enzyme 2 (ACE2) in SARS coronavirus-induced lung injury. Nature Medicine. 2005. PMID: 16007097

Questions

Angiotensin-converting enzyme, ACE, converts angiotensin I to angiotensin II. It is a zinc-dependent peptidyl dipeptidase anchored to the luminal surface of endothelial cells, and it removes the C-terminal dipeptide His-Leu from the decapeptide angiotensin I. The resulting octapeptide is angiotensin II, the active effector of the cascade.
The converting enzyme ACE performs this reaction. Its active-site zinc activates a water molecule that hydrolyses the bond between phenylalanine at position 8 and histidine at position 9 of angiotensin I. Chymase and a few other proteases can produce the same product in some tissues, particularly human heart, by cleaving the same bond.
ACE turns angiotensin I into angiotensin II by clipping off its last two residues. The enzyme is expressed most densely on pulmonary capillary endothelium, so plasma passing through the lung is converted efficiently in a single pass. Systemic endothelium, renal brush border and local tissue systems contribute as well.
Angiotensin-converting enzyme, classified as EC 3.4.15.1 and also called kininase II, converts angiotensin I to angiotensin II. The somatic form carries two catalytic domains, and the literature describes the C domain as dominant for angiotensin I hydrolysis under physiological chloride conditions. The reaction requires a free C-terminal carboxylate on the substrate.
A single hydrolysis by ACE changes angiotensin I to angiotensin II, removing the dipeptide His-Leu and leaving the octapeptide Asp-Arg-Val-Tyr-Ile-His-Pro-Phe. No cofactor peptide or second enzyme is required. Alternative proteases such as chymase and cathepsin G have been reported to generate the same octapeptide in certain tissue preparations.
The enzyme is ACE, angiotensin-converting enzyme, a type I membrane glycoprotein of the gluzincin metallopeptidase family with a HEXXH-type zinc-binding motif. A soluble ectodomain shed into plasma is also catalytically active, but membrane-bound enzyme on endothelial surfaces is treated in the literature as the main converter in the intact circulation.
Yes to both. Venous return carries angiotensin I to the pulmonary artery on every circuit, and the lung also expresses local renin-angiotensin components. Isolated perfused lung studies showed substantial single-pass conversion of angiotensin I to angiotensin II across the pulmonary bed, abolished by active-site ACE inhibitors.
No. ACE2 is a carboxypeptidase that removes one residue, giving angiotensin-(1-9) from angiotensin I and angiotensin-(1-7) from angiotensin II. Two independent 2000 reports in Circulation Research (PMID 10969042) and the Journal of Biological Chemistry (PMID 10924499) described this specificity and its insensitivity to classical ACE inhibitors.

RESEARCH USE ONLY · NOT EVALUATED BY THE FDA