HPLC Tested Thymosin Alpha-1 Research Peptide Sourcing
Short answer
An HPLC tested thymosin alpha-1 research peptide is lot-specific material whose chromatographic purity profile, molecular identity and documentation trail can be inspected before the material enters a laboratory workflow. Supplier evaluation for a 28-residue acetylated peptide turns on four checkable things: a reversed-phase chromatography result reported with its complete method conditions, an orthogonal identity confirmation by mass spectrometry, a certificate…
An HPLC tested thymosin alpha-1 research peptide is lot-specific material whose chromatographic purity profile, molecular identity and documentation trail can be inspected before the material enters a laboratory workflow. Supplier evaluation for a 28-residue acetylated peptide turns on four checkable things: a reversed-phase chromatography result reported with its complete method conditions, an orthogonal identity confirmation by mass spectrometry, a certificate of analysis that names the testing laboratory and the lot it belongs to, and a quotation that states the minimum order quantity, the lead time, the analytical package and the export documentation that travels with the shipment. Those attributes can be examined and compared. Brand reputation and anecdotal impressions cannot be examined in the same way.
What does HPLC testing establish for a thymosin alpha-1 research peptide?
Reversed-phase high performance liquid chromatography establishes a relative purity profile, which is a different statement from absolute purity. The technique separates peptide species by their hydrophobic interaction with a bonded stationary phase, usually an octadecylsilane (C18) material, as a gradient of organic solvent in water carries them off the column. The main peak is integrated against the total integrated area of all detected peaks, and the result describes how much of the chromatographically visible, light-absorbing material is the target species under one specific set of conditions.
That qualifier matters for thymosin alpha-1 in a way it does not for many other peptides. The sequence contains no tryptophan, no tyrosine and no phenylalanine, so there is no aromatic side chain to absorb near 280 nanometres. Detection therefore depends on the amide bond absorbance in the low ultraviolet region, in the vicinity of 214 to 220 nanometres, where the mobile phase modifier and the solvent front contribute their own background. A method that is poorly optimised in that region can bury small related peaks in baseline noise.
Chromatography also has structural blind spots. Two species with similar hydrophobicity can co-elute, so a single clean peak is evidence of homogeneity under those conditions rather than proof of a single molecular entity. Counterion, residual water and inorganic salts do not absorb meaningfully at the detection wavelength and are not represented in the chromatogram at all, which is why a chromatographic result and the composition of the weighed powder are two separate questions. An orthogonal run, at a different mobile phase pH or on a different stationary phase chemistry, is the usual way the literature describes strengthening a single-method conclusion.
Why does mass spectrometry matter alongside chromatography?
Mass spectrometry answers the question chromatography cannot: whether the material that elutes is the intended molecule. Electrospray ionisation of a peptide of this size generates a family of multiply charged ions, and deconvolution of that envelope yields a neutral mass that can be compared against the calculated value for the published molecular formula of thymosin alpha-1, C129H215N33O55, which corresponds to an average molecular mass near 3108 daltons. Agreement between the measured and calculated mass within the stated tolerance of the instrument is the primary identity evidence on most research peptide certificates.
Mass differences also characterise the impurity population in a way that retention time alone does not. Loss of the N-terminal acetyl group shifts the mass by 42 daltons. A deletion sequence is lighter by the residue mass of whichever amino acid failed to couple. Aspartimide formation removes a water molecule and shifts the mass by 18 daltons while potentially generating several chromatographically distinct isomers. Incomplete removal of a tert-butyl side chain protecting group adds 56 daltons. When a certificate reports both a chromatographic profile and the masses of the secondary peaks, the impurity population stops being anonymous.
The limits are equally worth stating. Ionisation efficiency varies between species, so peak intensity in a mass spectrum is not a quantitative purity measure without response-factor work. Isomers of identical mass, including beta-aspartyl rearrangement products and racemised diastereomers, are indistinguishable by mass alone and have to be resolved chromatographically or probed by tandem fragmentation. Mass spectrometry and chromatography are complementary, and a documentation package that carries only one of them is carrying half the evidence.
What belongs on a complete certificate of analysis?
A complete certificate of analysis identifies the material, identifies the batch, lists every test with its method and its result, and identifies the laboratory and the date on which release was signed. For thymosin alpha-1 the identification block normally carries the product name, the synonym thymalfasin, the CAS number 62304-98-7, the molecular formula, the calculated molecular mass and the full 28-residue sequence with its N-terminal acetyl group shown.
The analytical block carries the chromatographic purity result together with the conditions that produced it: column chemistry and dimensions, particle size, mobile phase composition for both channels, the gradient profile, flow rate, column temperature, the volume of sample introduced onto the column, the detection wavelength and the total run time. A purity figure quoted without those conditions cannot be reproduced or compared against another laboratory's figure, because the numbers are method-dependent.
Beyond chromatography and mass confirmation, a thorough certificate reports appearance, water content by Karl Fischer titration, counterion content, net peptide content with the method used to determine it, and residual solvents by headspace gas chromatography against the limits framework set out in the ICH Q3C guideline for residual solvents. Bacterial endotoxin may appear where it has been contracted. Storage conditions for the sealed container and a retest date complete the document, along with the lot number, the manufacturing date, the name of the analytical laboratory and the signature or electronic approval of the releasing analyst.
Real Peptides publishes independent third-party certificates of analysis for every batch, and those certificates are posted publicly at /coas/ rather than released only on request, which means a document can be located by lot number and read before an order is placed. The catalog listing for the compound itself sits at thymosin alpha-1.
How can a certificate be cross-checked against its chromatogram?
Cross-checking is a matter of comparing fields that have to agree. The chromatogram carries an acquisition date, a sample identifier, a method file name and an instrument identifier, and those fields are either consistent with the certificate or they are not. The lot number printed on the certificate ought to appear in the sample identifier of the raw trace. The retention time of the main peak in the integration table ought to match the retention time quoted in the certificate text.
The integration table itself is where the detail lives. It lists each detected peak with its retention time, its area and its relative area, and it reveals whether secondary peaks were reported individually or lumped into a single total impurities line. A stated disregard limit, below which peaks are excluded from the calculation, changes the headline result and belongs in the method description. Baseline quality, peak symmetry and the resolution between the main peak and its nearest neighbour are visible in the trace and not in the summary figure.
A chromatogram that has been cropped to show only the main peak, or printed without axis labels, scale or header fields, conveys an impression rather than a result. Similarly, a mass spectrum presented as a single annotated number, with no spectrum and no deconvolution output, cannot be checked against the calculated mass of the sequence. Documentation that survives this kind of inspection is the practical difference between material described as tested and material whose testing can be followed from the instrument to the certificate.
Which impurities does a 28-residue synthetic peptide tend to carry?
The impurity population of a solid-phase synthetic peptide is predictable from its chemistry, and the thymosin alpha-1 sequence predicts a specific set. The chain is Ac-Ser-Asp-Ala-Ala-Val-Asp-Thr-Ser-Ser-Glu-Ile-Thr-Thr-Lys-Asp-Leu-Lys-Glu-Lys-Lys-Glu-Val-Val-Glu-Glu-Ala-Glu-Asn, an acidic, highly polar molecule rich in aspartate and glutamate and free of aromatic and sulfur-containing residues.
Deletion and truncation sequences arise wherever a coupling step runs incompletely, and they are the most common related substances in any 28-mer. Des-acetyl material arises where the final capping step is incomplete. Aspartimide formation is a particular concern in this sequence because aspartate residues followed by small or hydroxyl-bearing residues, such as the Asp-Ala and Asp-Thr motifs present here, are the classic context for ring closure during repeated base treatment; the resulting aspartimide can open to the alpha-peptide or to the beta-aspartyl isomer, and the beta isomer is a same-mass impurity that only chromatography will resolve. Racemisation during activation produces diastereomeric impurities with the same mass as well.
Incomplete side-chain deprotection leaves tert-butyl and related adducts on the many acidic and hydroxyl-bearing residues. Scavenger adducts from the cleavage cocktail, trifluoroacetate counterion carried over from preparative purification, residual acetonitrile, and adsorbed water from a hygroscopic lyophilised powder complete the picture. Oxidation, which dominates the impurity discussion for methionine-, cysteine- and tryptophan-containing peptides, is a minor concern here because none of those residues is present. A certificate that names the impurity classes it tested for, rather than reporting a single aggregate figure, is describing a controlled process.
What does net peptide content mean and why does it differ from a chromatographic result?
Net peptide content and chromatographic purity answer two different questions about the same vial. Chromatographic purity asks what proportion of the peptide-related, UV-absorbing material is the target sequence. Net peptide content asks what proportion of the weighed powder is peptide at all, with the remainder being water, counterion, residual salts and residual solvent. A lot can be chromatographically homogeneous and still consist, by mass, of a substantial fraction of non-peptide material, because lyophilised acidic peptides retain water and because preparative purification leaves a trifluoroacetate or acetate counterion associated with every basic site.
The determination methods are well established. Quantitative amino acid analysis hydrolyses a sample and quantifies the liberated residues against internal standards. Elemental nitrogen determination infers peptide mass from nitrogen content. Quantitative nuclear magnetic resonance against a certified internal standard is used where the facility has the instrument time. Each has its own uncertainty, and the certificate that names the method allows that uncertainty to be judged.
The consequence is arithmetic rather than interpretive. A container labelled as holding 10 mg of material, taken into 10 mL of solvent, gives a nominal 1 mg per mL of powder, not of peptide; if net peptide content is materially below the label mass, the peptide concentration of that nominal solution is correspondingly lower. Laboratories that normalise results across lots generally work from net peptide content rather than from gross label mass, because the gross figure drifts with water uptake and counterion load between batches. Material offered without a net peptide content determination leaves that correction undefined.
Which identity attributes confirm that material is thymosin alpha-1?
Identity confirmation rests on a small set of attributes that can be checked against public chemical records before procurement. The CAS registry number is 62304-98-7. The international non-proprietary name is thymalfasin. The molecule is the acetylated N-terminal 28-residue fragment of prothymosin alpha, so an identity claim has to account for both the chain length and the N-terminal acetyl group, since des-acetyl material is a different molecular entity with a different mass.
The molecular formula C129H215N33O55 and its calculated average mass near 3108 daltons are the reference values against which a deconvoluted electrospray mass is compared. The single-letter sequence SDAAVDTSSEITTKDLKEKKEVVEEAEN, with the acetyl group at the amino terminus and a free acid at the carboxy terminus, is the reference against which a tandem fragmentation experiment or an amino acid analysis can be judged.
Confusion with other thymic peptides is the practical risk in procurement. Thymosin beta-4 and its commonly supplied fragment are unrelated sequences of different length and different registry numbers, and the catalog entry for that material is listed separately as TB-500. Thymosin alpha-1 is also distinct from thymosin fraction 5, the partially purified thymic extract from which the thymosins were originally characterised. A listing that names a compound without giving a registry number, a formula and a sequence is making an identity claim that cannot be checked, and checking it is the first step of any comparison between suppliers.
What do water content, counterion and residual solvent results tell a laboratory?
These three tests describe everything in the container that is not peptide, and they explain most of the mass discrepancy between label weight and peptide weight. Water content by Karl Fischer titration quantifies the moisture retained after lyophilisation and taken up afterwards. Acidic peptides of this type are hygroscopic, and a lot with elevated water content behaves differently on the balance and may be less stable in storage than a well-dried lot.
Counterion identity and content follow from how the material was purified. Preparative reversed-phase purification with trifluoroacetic acid as the mobile phase modifier leaves trifluoroacetate paired with the basic residues, and the thymosin alpha-1 sequence carries several lysines. Where a laboratory works with cultured cells, the literature describes residual trifluoroacetate as a variable that can influence cell viability and assay readouts, which is why acetate-exchanged material and an ion chromatography result for counterion content are sometimes specified. A certificate that records which counterion is present removes a confounder from the experimental record.
Residual solvents are determined by headspace gas chromatography and judged against the class limits of the ICH Q3C framework. For a peptide purified in water and acetonitrile and cleaved with reagents that include volatile scavengers, acetonitrile is the solvent most often reported. None of these three results speaks to the identity or the chromatographic quality of the peptide; they speak to the composition of the powder, and they are the fields most often absent from thin documentation packages.
Is endotoxin or sterility testing part of a research peptide certificate?
Usually not by default. Lyophilised research-grade peptide is generally supplied as non-sterile material, and a standard certificate reports identity, chromatographic profile and composition rather than microbiological attributes. Where a laboratory works with cell cultures or with animal models, bacterial endotoxin becomes relevant, and testing by the limulus amebocyte lysate method, or by the recombinant factor C alternative, is contracted as an additional specification on the lot.
Bioburden and sterility are separate determinations again, with their own methods and their own sampling requirements, and they are normally associated with materials produced under pharmaceutical manufacturing conditions rather than with research chemicals. A supplier of research-use material can reasonably state that a given lot was not tested for endotoxin; what matters for comparison is that the certificate says so plainly rather than leaving the reader to assume one way or the other.
The practical consequence is that endotoxin status belongs in the quotation conversation rather than being assumed from a purity figure. A chromatographically clean peptide can carry endotoxin introduced from water, glassware or handling, because endotoxin is not a peptide-related impurity and will not appear in a reversed-phase chromatogram. Where endotoxin has been measured, the certificate records the method, the limit applied and the result for that specific lot, and where it has not been measured, the absence of the test is itself information.
What does a bulk thymosin alpha-1 API or raw powder quotation typically cover?
A quotation request for bulk active pharmaceutical ingredient or raw powder is a request for a defined set of commercial and technical parameters, and the ones that make quotations comparable are consistent across the industry: the minimum order quantity, the lead time with its components identified, the analytical package that accompanies the lot, the packaging and labelling format, and the export documentation available for the destination country. A reply that names all five can be compared against another reply that names all five.
The analytical package is the part most often left vague. A comparable quotation states which tests will be performed, by which laboratory, and whether raw data such as chromatograms and mass spectra are supplied alongside the summary certificate. It also states whether testing is performed in-house, by an independent contract laboratory, or both, and whether retain samples are held against future queries.
Packaging and labelling cover container type, closure, fill tolerance, inner packaging against moisture, and the label fields carried on each container, including lot number, net content, storage condition and a research-use-only statement. Export support covers the commercial documents a shipment requires and the temperature control used in transit.
Numerical values for minimum order quantity and lead time are not set by any published standard; they are specific to the manufacturing route, the scale and the analytical scope requested, and they are stated in the quotation itself rather than being inferable from a catalog page. Real Peptides lists its research-use catalog at /shop/ and publishes its operating location details at /location/.
How is lead time structured in peptide supply?
Lead time for a synthetic peptide is the sum of several distinct stages, and a quotation that names the stages is more useful than one that quotes a single figure. The stages are scheduling against existing production commitments, solid-phase chain assembly, cleavage from the resin with side-chain deprotection, preparative purification, counterion exchange where it has been specified, lyophilisation, quality control testing, document preparation and release, packaging, export paperwork and transit.
Sequence chemistry affects the middle stages. A 28-residue acidic peptide with multiple aspartate-containing motifs is prone to aspartimide-derived related substances, and controlling them can mean a slower assembly strategy, modified base conditions or a more demanding purification that sacrifices recovery in order to resolve same-mass isomers. Larger scale does not simply multiply the time, because preparative purification becomes the rate-determining step and may require repeated loading cycles.
Quality control is its own block of time. Chromatographic and mass spectrometric work can be completed quickly, while amino acid analysis, residual solvent determination and any contracted endotoxin or third-party confirmation run on the external laboratory's schedule. Documentation and release add further time where a second analyst reviews the data before signature.
No published standard sets a lead time for research peptide manufacture, and figures quoted in general sourcing discussions are not specifications. The verifiable version is the one written into the quotation for the specific scale and the specific analytical scope, with the stages identified so that a delay in one of them can be located rather than guessed at.
What export and shipping documentation accompanies an international research shipment?
International movement of research chemicals depends on commercial and regulatory documents rather than on the analytical package. The commercial invoice and packing list describe the goods, the quantity, the value and the parties. A harmonised system tariff classification determines the customs treatment in the destination country. A safety data sheet prepared under the Globally Harmonized System describes hazard classification, handling precautions and transport information for the material as supplied.
A research-use-only declaration, stating that the material is not intended for human or veterinary consumption, is routinely requested by customs authorities for peptide shipments, and a certificate of origin is required by some destinations. Import permits, controlled-substance checks and prior notification requirements vary by jurisdiction and are set by the importing country rather than by the exporter, so the list of required documents is destination-specific and no universal list exists.
Temperature control is the other half of export support. Lyophilised peptide is shipped with coolant appropriate to the transit time, in insulated packaging, and in some arrangements with a temperature data logger whose record is read on arrival. The certificate of analysis specifies the storage condition for the sealed container, and the shipping method is chosen to keep the material within that condition for the duration of transit.
A supplier that can state which of these documents it issues as standard, and which it can prepare on request for a given destination, is describing an operational capability that can be verified by inspecting the paperwork from a previous shipment.
How does independent third-party testing differ from in-house quality control?
In-house quality control and independent third-party testing serve different functions and are not substitutes for one another. In-house quality control is the manufacturer's own release testing, performed on its instruments by its analysts against its specifications, and it is the mechanism by which a lot is approved for release at all. Third-party testing is a separate determination performed by a laboratory with no commercial interest in whether the lot passes.
The value of the second determination lies in its independence of the first. A contract laboratory receives a sample identified by lot, runs its own method, and issues a report under its own name and accreditation. Where the two results agree, the agreement is evidence that the result is a property of the material rather than of the method or the operator. Where they disagree, the discrepancy itself is informative and is usually investigated before release.
Accreditation status, the scope of that accreditation and the methods used are the attributes that distinguish one third-party report from another. A report that names the laboratory, the method, the instrument and the analyst can be followed up; one that shows a figure on unattributed letterhead cannot.
For comparison purposes, the useful question is not whether a supplier claims testing but whether a lot-specific report is retrievable and attributable. Certificates posted publicly and indexed by lot, as at /coas/, allow that retrieval before purchase rather than after it.
How can the question of the best thymosin alpha-1 brand be answered with documentation?
The best-brand question becomes answerable when it is restated as a documentation comparison, because the attributes that differ between suppliers are documentary and analytical rather than reputational. The comparable attributes are these: whether a certificate of analysis exists for the specific lot in hand rather than for a representative batch; whether that certificate is retrievable by lot number without a request; whether an independent laboratory performed any part of the testing; whether raw chromatograms and mass spectra are supplied alongside the summary; whether the chromatographic method conditions are stated in full; whether net peptide content, water content, counterion and residual solvents are reported; whether identity is anchored to a registry number, a formula and a sequence; and whether the label and the documentation describe the material as research use only.
A supplier that satisfies all of those can be compared with another supplier that satisfies all of those, and the comparison then moves to operational factors such as lot-to-lot consistency across repeat orders, the completeness of export paperwork and the responsiveness of the quotation process. A supplier that satisfies none of them has provided nothing to compare.
Nothing in that list depends on a ranking, a top-ten listing or an aggregate rating. Rankings of research chemical vendors are compiled without access to the analytical data for any particular lot, and a lot is the unit that a laboratory actually receives. Two lots from the same manufacturer can differ in water content, counterion load and related-substance profile, which is precisely why documentation is lot-specific and why brand-level judgements carry limited information about the container on the bench.
What do thymosin alpha-1 peptide reviews leave undetermined?
Written impressions of a research peptide can describe the things a purchaser perceives directly: how quickly a parcel arrived, how it was packed, whether the label matched the order, whether the powder looked like a well-formed cake or a collapsed residue, and how a query was handled. Those observations are real, and they describe service and presentation.
They do not determine molecular identity, because identity requires a mass measurement. They do not determine chromatographic purity, because purity requires a separation with a defined method. They do not determine net peptide content, counterion load, water content, residual solvent or endotoxin, because each of those requires a specific analytical procedure on a specific sample. The appearance of a lyophilised cake is influenced by fill volume, shelf temperature profile and residual moisture, and a visually unremarkable cake carries no information about the impurity profile of the material inside it.
The assessable evidence about a compound divides into two bodies. The first is the published scientific literature, which describes what the molecule is and what has been observed in defined models. The second is the analytical documentation for a particular lot, which describes what is in a particular container. Both are inspectable by a third party. Neither is replaced by an aggregate of individual impressions, and the practical effect of relying on documentation is that a disagreement about quality becomes a question about data rather than a question about opinions.
What does the published literature report about thymosin alpha-1?
Thymosin alpha-1 is the acetylated 28-residue amino-terminal fragment of prothymosin alpha, originally characterised from thymic tissue preparations, and the published literature describes it as an immunomodulatory peptide that acts on dendritic cell and T lymphocyte function rather than as a direct antimicrobial or cytotoxic agent. Research suggests its activity involves pattern recognition receptor signalling and the maturation state of antigen-presenting cells, with downstream effects on T cell differentiation reported across in vitro and animal models.
Preclinical work has examined the molecule in models of chronic inflammation. The study reported as Thymosin alpha1 represents a potential potent single-molecule-based therapy for cystic fibrosis, published in Nature Medicine in 2017, described effects on inflammatory signalling and on CFTR-related endpoints in murine models and in cells derived from affected individuals. As preclinical work, it establishes mechanism and plausibility in defined systems, not clinical outcome, and findings in murine models do not transfer automatically to human physiology.
Clinical-program reporting during the 2020 pandemic included Thymosin alpha 1 reduces the mortality of severe coronavirus disease 2019 by restoration of lymphocytopenia and reversion of exhausted T cells in Clinical Infectious Diseases, which reported associations between the compound and lymphocyte recovery in hospitalised patients with severe disease. That report is observational in design, and observational comparisons carry confounding by indication and by concurrent care that randomised designs are built to control, so the finding is best described as an association reported in one cohort rather than as a demonstrated effect.
For a laboratory sourcing material to study any of this, the relevance of the literature is that it defines the molecular entity under investigation. A study of thymosin alpha-1 performed with des-acetyl material, with a deletion-rich lot or with a powder whose peptide content is undefined is not a study of the same molecule, which is why identity confirmation precedes experimental design.
What storage and handling specifications appear on documentation for lyophilised material?
Certificates and labels for lyophilised peptide state a storage condition for the sealed container, most commonly cold or frozen storage with protection from light and moisture, together with a retest or re-evaluation date. Those specifications describe the powder as supplied, and they exist because peptide degradation in the solid state is driven largely by residual moisture, temperature and exposure to atmospheric water once a container is opened.
The chemistry behind the specification is sequence-dependent. The literature describes aspartate- and asparagine-containing sequences as susceptible to deamidation and isomerisation, and the thymosin alpha-1 sequence carries several aspartate residues and a carboxy-terminal asparagine, which makes those pathways the ones most likely to generate same-mass or near-mass related substances over time. Hygroscopic powders that take up water also sinter and discolour, and a change in cake appearance across storage is a recognised prompt for re-analysis.
Freeze-thaw cycling is a recognised physical stress, and the literature consistently reports that repeated cycles are more damaging than a single freezing event, which is why storage documentation for research materials emphasises stable conditions rather than convenient access. Light protection appears on labels because photochemical pathways affect peptides even without aromatic residues, through trace metal catalysis and oxidative chemistry involving residual solvent and water.
A documentation package that reports water content at release, states the storage condition, and sets a retest interval allows a laboratory to judge whether material held for a period remains fit for the comparison it was bought for. Real Peptides does not provide preparation or use guidance for any catalog compound, because these are research-use-only materials supplied for laboratory investigation.
How does thymosin alpha-1 compare with TB-500 from a documentation standpoint?
The two compounds are often held in the same freezer and are often confused in procurement, but their analytical profiles differ enough that the same certificate template does not serve both well. Thymosin alpha-1 is a 28-residue acetylated acidic peptide with no aromatic residues, which places its chromatographic detection in the low ultraviolet region and makes aspartimide-derived isomers the characteristic related substances. The fragment supplied as TB-500 is a shorter sequence derived from thymosin beta-4, with its own registry number, its own molecular formula and its own impurity chemistry, and the catalog entry for it is listed as TB-500.
For a facility that handles both, cross-contamination control is part of the quality story: dedicated or thoroughly cleaned preparative equipment, segregated lyophilisation runs and analytical methods capable of resolving one from the other. A mass spectrometric identity check distinguishes them unambiguously because their masses differ substantially, which is one reason mass confirmation belongs on every certificate rather than only on first-time lots.
The documentation comparison, then, runs along the same axes for both compounds: identity anchored to registry number, formula and sequence; chromatographic profile with stated conditions; mass confirmation with the deconvoluted result; composition data covering water, counterion and residual solvent; and a lot-specific certificate that names its laboratory. Where those fields are present for both compounds, the two can be handled under one quality system. Where the fields differ in completeness between two products from the same source, that difference is itself worth noting during supplier evaluation.
All compounds discussed on this page are sold for laboratory research use only and are not for human consumption.
References
- Thymosin alpha1 represents a potential potent single-molecule-based therapy for cystic fibrosis. Nature Medicine. 2017. PMID: 28394330. pubmed.ncbi.nlm.nih.gov/28394330
- Thymosin alpha 1 reduces the mortality of severe coronavirus disease 2019 by restoration of lymphocytopenia and reversion of exhausted T cells. Clinical Infectious Diseases. 2020. PMID: 32442287. pubmed.ncbi.nlm.nih.gov/32442287
Build a pack
Researching more than one compound?
Build a multi-vial pack and the discount applies automatically as you add vials.
Questions
RESEARCH USE ONLY · NOT EVALUATED BY THE FDA