Ships within 24 hours on business days · +10% with Bank Pay

IGF-1 LR3

Shop

IGF-1 LR3 · Research brief

What Is Octreotide? The Somatostatin Analog Explained

60 WORDS

Short answer

Octreotide is a synthetic eight-residue peptide analog of the natural hormone somatostatin, engineered to resist rapid enzymatic breakdown in plasma and to bind preferentially at somatostatin receptor subtype 2, with lower but pharmacologically meaningful affinity at subtype 5. Put in one line, what is octreotide comes down to this: a cyclic octapeptide closed by a disulfide bridge between two cysteine…

Octreotide is a synthetic eight-residue peptide analog of the natural hormone somatostatin, engineered to resist rapid enzymatic breakdown in plasma and to bind preferentially at somatostatin receptor subtype 2, with lower but pharmacologically meaningful affinity at subtype 5. Put in one line, what is octreotide comes down to this: a cyclic octapeptide closed by a disulfide bridge between two cysteine residues, carrying D-configuration amino acids at two positions and a reduced threoninol group at its C-terminal end, modifications that together slow its degradation relative to the parent hormone. In clinical medicine the molecule appears as octreotide acetate, a salt form whose approved labeling covers acromegaly and the symptomatic features of certain hormone-secreting neuroendocrine tumors. In the laboratory it is one of the most widely used pharmacological tools for suppressing growth hormone release and for probing somatostatin receptor biology in cell systems and animal models. Real Peptides supplies octreotide as a research-use-only compound for laboratory investigation, not as a drug product.

What does octreotide mean, and what kind of molecule does it name?

Octreotide names one specific synthetic molecule, not a family of related compounds. The name encodes the chemistry: the first element points to its eight amino acid residues, and the closing stem marks it as a peptide under international nonproprietary naming conventions, where that ending is reserved for peptide compounds.

The molecular formula generally reported for the free peptide base is C49H66N10O10S2, with a molecular weight near 1,019 g/mol, and the free peptide is registered under CAS number 83150-76-9. Its sequence is written D-Phe-Cys-Phe-D-Trp-Lys-Thr-Cys-Thr(ol), where Thr(ol) indicates threoninol, a threonine residue reduced to the corresponding amino alcohol at the C-terminus. The two cysteine residues form an intramolecular disulfide bridge, which closes the chain into a ring and constrains its conformation.

That ring is the point of the design. Native somatostatin-14 presents a beta turn containing the Phe-Trp-Lys-Thr motif, and structural pharmacology describes this turn as the region that makes contact with somatostatin receptors. The synthetic analog preserves that motif inside a much smaller cyclic scaffold, so the recognition element is retained while most of the flanking sequence is discarded. Substituting the D isomer of tryptophan at the key position and capping the chain with an amino alcohol removes two of the sites where endogenous peptidases would normally cleave a linear peptide, which is why the analog persists in biological fluids far longer than the hormone it mimics.

Chemically, then, this is a conformationally restricted peptidomimetic rather than a simple fragment. It is a small molecule by peptide standards, soluble in aqueous buffers, and supplied for research as a lyophilized powder. Its identity in a laboratory setting is confirmed the same way any peptide identity is confirmed: by mass spectrometry against the expected molecular weight and by chromatographic behavior against a reference standard.

What is octreotide acetate, and how does it differ from the base peptide?

Octreotide acetate is the acetate salt of the same octapeptide. The peptide carries basic groups, most notably the lysine side chain and the free N-terminal amine, and during purification and lyophilization those groups are paired with acetate counterions. The result is a solid that handles better, dissolves more predictably in aqueous media, and is the form in which the molecule is almost always supplied, both as a pharmaceutical ingredient and as a research chemical.

The pharmacologically active species is identical. Once the salt enters solution, the counterion dissociates and the receptor sees the same cyclic octapeptide. What changes is the bookkeeping. Gross powder weight in a salt preparation includes acetate and residual water, so the net peptide content is lower than the total weight of the solid. Peptide content varies between lots and is reported on the certificate of analysis rather than assumed. Chemical registries list salt forms under their own identifiers, which is why a catalog entry for the free peptide and an entry for a salt preparation may not carry the same registry number.

Asking what is octreotide acetate used for therefore has two answers that should not be blurred. In pharmaceutical products, the acetate salt is the ingredient named in approved labeling, and the indications attached to those products are regulatory facts attached to a finished, quality-controlled medicine. In the laboratory, the acetate salt is simply the convenient form of a receptor-selective agonist used to interrogate somatostatin receptor signaling in cells, tissues and animal models. Research-grade material supplied by Real Peptides falls entirely in the second category and carries no clinical status of any kind.

For laboratories comparing material across suppliers, molecular identity is the thing to verify first: the expected molecular weight, the registry number for the form being purchased, and a lot-specific analytical record. Real Peptides publishes independent third-party certificates of analysis for every batch at /coas/.

What is octreotide and how does it work at somatostatin receptors?

Octreotide works by occupying somatostatin receptors, a family of five G protein-coupled receptors designated SSTR1 through SSTR5, and reproducing part of the inhibitory signal that native somatostatin produces when it binds them. The analog is not evenly selective across that family. Binding studies consistently describe high affinity at SSTR2, moderate affinity at SSTR5, measurable but weaker affinity at SSTR3, and little meaningful interaction with SSTR1 or SSTR4. That profile is the single most important fact about its pharmacology, because it means the compound reports on a subset of somatostatin biology rather than on the whole system.

Downstream, the somatostatin receptors couple predominantly to inhibitory G proteins of the Gi and Go classes. Receptor occupancy suppresses adenylyl cyclase activity and lowers intracellular cyclic AMP, activates inwardly rectifying potassium conductances that hyperpolarize the cell membrane, and reduces voltage-gated calcium entry. In a secretory cell, those three changes converge on the same outcome: fewer calcium-dependent fusion events at the plasma membrane and therefore less release of stored hormone. The literature also describes recruitment of protein tyrosine phosphatases, including the SHP family, as a second arm of signaling associated with antiproliferative effects in some cell systems, though research in that area is more heterogeneous than the secretory work.

Receptor internalization matters for experimental design. SSTR2 is described as internalizing readily after agonist binding, which underlies the use of radiolabeled somatostatin analogs for imaging receptor-expressing tissue and which also means that sustained exposure in culture can change surface receptor density over hours. Studies that report a diminished response after prolonged exposure are often reporting receptor trafficking rather than loss of compound activity.

Because the affinity profile is skewed, experiments using this analog are probing SSTR2-dominant signaling with a secondary SSTR5 component. Where an investigator needs broader subtype coverage, the literature points to analogs with different binding profiles, which is why subtype selectivity is reported alongside any functional readout.

What does octreotide do to hormone secretion in model systems?

What octreotide does, in the broadest functional terms, is inhibit regulated secretion from cells that express the receptor subtypes it binds. The most thoroughly characterized example is the pituitary somatotroph, where receptor occupancy suppresses growth hormone release, both basal and stimulated. Because circulating insulin-like growth factor 1 is produced largely in response to growth hormone signaling at the liver, suppression upstream is reflected downstream as lower IGF-1, and IGF-1 is accordingly used as the integrated biochemical readout of growth hormone axis suppression in both clinical and preclinical work.

The inhibitory reach extends well beyond the pituitary. Research describes suppression of glucagon and insulin release from pancreatic islets, reduced output of gastrin, secretin, motilin, vasoactive intestinal peptide and pancreatic polypeptide from gut endocrine cells, and reduced serotonin release from enterochromaffin-derived tumor cells. Because insulin and glucagon are both suppressed, the net effect on glucose handling in any given model is not fixed; it depends on which arm dominates in that preparation, and published work reports movement in both directions depending on species and metabolic state.

There is also a non-endocrine component. Studies describe reduced splanchnic blood flow, slowed gastrointestinal transit, and reduced net fluid and electrolyte secretion across intestinal epithelium. These effects are mechanistically distinct from hormone suppression, since epithelial transport is governed by cyclic AMP and calcium signaling within enterocytes themselves, and somatostatin receptors expressed on those cells, on enteric neurons and on immune cells can all contribute.

For laboratory use, the practical consequence is that a single compound produces several simultaneous changes in any intact preparation. Isolated cell work gives cleaner attribution; whole-animal work gives physiological relevance at the cost of mechanistic ambiguity. Published studies that report a change in one secretory endpoint routinely acknowledge that neighbouring axes were also affected.

What is octreotide used for in approved clinical practice?

In approved clinical practice, the labeling for octreotide acetate products covers a short and specific list. The first is acromegaly, where the goal is biochemical control of growth hormone and IGF-1 in patients whose disease is not adequately controlled by surgery or radiation. The second is control of the severe diarrhea and flushing associated with metastatic carcinoid tumors. The third is control of the profuse watery diarrhea associated with vasoactive intestinal peptide secreting adenomas. These are regulatory facts about finished medicines, reported here as such.

All three indications share a mechanism. Each involves a tissue that over-secretes a hormone or bioactive amine and that expresses somatostatin receptors, so a receptor-selective inhibitory agonist reduces the secretory output and, with it, the clinical features that output drives. In acromegaly the output is growth hormone; in carcinoid syndrome it is serotonin and related mediators; in the VIP-secreting syndrome it is vasoactive intestinal peptide acting on intestinal epithelium. The clinical picture differs, the pharmacology does not.

A question phrased as what is octreotide given for therefore has the same bounded answer in the approved setting: suppression of pathological hormone secretion in those defined conditions, and the symptomatic consequences that follow from that suppression. Formulations include an immediate-release solution and a long-acting depot preparation that releases peptide gradually over a period of weeks, the latter developed to maintain receptor occupancy over longer intervals than the short circulating lifetime of the free peptide allows.

Claims that reach past that list belong to a separate body of investigational and off-label reporting, summarized further down, and that literature does not carry the same evidentiary weight as a regulatory indication. Nothing in either body of work transfers to research-grade material, which is not a medicine, is not manufactured as one and is supplied only for laboratory investigation. Catalog compounds are listed at /shop/.

What is octreotide used to treat beyond acromegaly and carcinoid syndrome?

Beyond the labeled indications, the published medical literature describes a wide range of investigational and off-label applications, and the strength of the supporting evidence varies considerably from one to the next. Reports describe its use in acute variceal bleeding on the rationale of reduced splanchnic blood flow, in chylous effusions and lymphatic leaks, in dumping syndrome after gastric surgery, in high-output pancreatic and enterocutaneous fistulas, in refractory hypoglycemia following sulfonylurea exposure, and in secretory diarrheas of several causes. Some of these are supported by controlled trials, others by case series and institutional experience.

A separate strand concerns oncology. Because SSTR2 is expressed at high density on many neuroendocrine tumors, somatostatin analogs serve both as a vehicle for receptor-targeted imaging and radioligand approaches and as agents investigated for effects on tumor growth rather than on symptoms alone. Antiproliferative signaling through receptor-associated phosphatases is the usual mechanistic rationale offered, and research in this area is ongoing rather than settled.

Another strand concerns the growth hormone and IGF-1 axis in diseases where that axis is thought to contribute. The phase II study discussed below, in non-metastatic castration-resistant prostate cancer, sits in this category: the hypothesis is upstream suppression of a growth-promoting axis rather than direct cytotoxicity.

What can octreotide be used for in a laboratory context is a different question again, and a broader one. As a receptor-selective tool it is used to test whether a given secretory or transport response depends on somatostatin receptor signaling, to silence hormone release in a preparation so that another variable can be isolated, and to characterize receptor expression in tissue. The investigational clinical literature and the mechanistic laboratory literature inform each other, but findings from one are not evidence in the other, and hedged language is appropriate throughout both.

What is octreotide medication, and how does research-grade material differ?

Octreotide medication refers to a finished pharmaceutical product containing octreotide acetate as its active ingredient, manufactured under pharmaceutical quality systems, sterile, formulated with excipients, assigned a regulatory status and sold against approved labeling that names its indications, contraindications and warnings. That product is the only form to which the clinical literature and the approved indications apply.

Research-grade material is a different article in every legal and practical sense. It is a chemical supplied to laboratories for in vitro and preclinical work. It carries no approved indication, no clinical status and no regulatory authorization for human use. It is characterized for identity and composition rather than formulated for a patient, and its documentation is an analytical record, not a package insert. Asking what is octreotide medication used for is therefore answered from regulatory labeling, while asking what a research laboratory does with the compound is answered from the experimental literature.

The practical distinction matters when a laboratory compares published clinical reports against its own bench work. A trial report describes a defined pharmaceutical product given under medical supervision with defined endpoints. A cell-culture study describes a defined concentration of a characterized chemical applied to a defined preparation. Both can be about the same molecule and still be answering different questions with different levels of control.

Real Peptides supplies research-use-only compounds and publishes independent third-party certificates of analysis for every batch, so that molecular identity, registry number and lot documentation can be verified before procurement. Facility and logistics details are listed at /location/. That is the extent of the supplier relationship: material and documentation for laboratory investigation, with no preparation or use guidance of any kind, because these compounds are research materials.

What is octreotide given for in gastrointestinal secretion research?

In gastrointestinal research, this analog is given in experimental preparations to test whether a secretory response depends on somatostatin receptor signaling. Intestinal epithelium moves fluid and electrolytes under the control of cyclic AMP and intracellular calcium, and many secretagogues, whether bacterial toxins, neuropeptides or immune mediators, converge on those second messengers. Because somatostatin receptor occupancy lowers cyclic AMP and alters ion conductances, an inhibitory analog is a direct way to ask whether a candidate secretagogue acts through a pathway that this receptor family can oppose.

A published example of exactly that design is Peptides of human immunodeficiency virus (HIV) evoke rat colonic electrolyte secretion inhibitable by the somatostatin analog octreotide, 1991. The report describes HIV-derived peptides evoking electrolyte secretion in rat colonic tissue, measured as a change in transepithelial electrolyte transport, and reports that the somatostatin analog inhibited that evoked secretory response. The finding supports two separate inferences: that specific viral peptides can act as secretagogues on colonic epithelium, and that the resulting secretion is sensitive to somatostatin receptor activation.

The limits of that model are worth stating plainly. It is a rodent tissue study examining an acute, evoked response to applied peptides, not a model of clinical disease, and inhibition of a response in rat colon does not establish what happens in human intestine, where receptor subtype distribution and epithelial transport machinery differ. Nor does inhibition of an evoked response identify the cell type carrying the receptor, since somatostatin receptors are present on enterocytes, enteric neurons and immune cells alike.

What the study does provide is a clean demonstration of the analog functioning as a pharmacological probe: an evoked physiological response, a selective agonist applied against it, and a measurable inhibition. That structure, stimulus and selective blockade, is the standard shape of research in this area.

What did the phase II prostate cancer study report about IGF-1?

A published phase II report examined whether this analog moved the growth hormone and IGF-1 axis in a defined oncology population. Effect of the somatostatin analog octreotide acetate on circulating insulin-like growth factor-1 and related peptides in patients with non-metastatic castration-resistant prostate cancer: results of a phase II study, 2012 reports on participants with non-metastatic castration-resistant prostate cancer and takes circulating IGF-1 and related peptides as its measured readout rather than a survival or imaging endpoint.

The rationale follows directly from the receptor pharmacology described above. Suppressing growth hormone release at the pituitary lowers hepatic IGF-1 production, and IGF-1 signaling has been investigated as a growth-promoting input in several tumor types. A study of this design is therefore asking a pharmacodynamic question first: in this population, under the trial's assigned amounts and schedule of the long-acting formulation, does the circulating axis actually move, and by how much relative to baseline.

The constraints on interpretation are substantial and are characteristic of phase II work. The study population is narrow and specifically defined, the design is early-phase rather than randomized against a comparator arm, and the primary readout is a circulating biomarker rather than a clinical outcome. A change in IGF-1 demonstrates that the compound engaged its intended axis in those participants; it does not by itself demonstrate benefit, and the authors of early-phase biomarker studies generally frame their findings that way.

For laboratory work, the value of such a report is as a bridge. It confirms in a human setting the same axis suppression that cell and animal models predict, which strengthens the case for IGF-1 as a translational marker of receptor engagement. Research suggests the pharmacodynamic link is robust across settings; what remains unsettled is whether moving that marker changes disease trajectory in this population.

How does octreotide differ from native somatostatin?

The two molecules differ in size, stability and receptor coverage. Native somatostatin exists in two principal forms, a 14-residue and a 28-residue peptide, both produced by processing of a common precursor. Both bind all five receptor subtypes with broadly comparable affinity, which makes the natural hormone a pan-subtype agonist. Both are also degraded extremely rapidly in plasma by peptidases, with a circulating lifetime measured in minutes, which is appropriate for a local paracrine signal and useless for sustained pharmacology.

The synthetic analog solves the stability problem and sacrifices breadth to do it. Reducing the chain to eight residues, cyclizing it through a disulfide bridge, installing D-amino acids at two positions and capping the C-terminus with an amino alcohol produces a molecule that resists the proteases that destroy the hormone. The reported circulating lifetime is longer by a large factor, measured in hours rather than minutes for the immediate-release form. The cost is selectivity: by keeping only the Phe-D-Trp-Lys-Thr recognition motif in a constrained ring, the analog binds SSTR2 and SSTR5 well and the remaining subtypes poorly.

That trade is the reason the two are not interchangeable in experiments. Native somatostatin applied to a preparation engages every receptor subtype present, so a response to it establishes somatostatin sensitivity without identifying the responsible subtype. The analog engages a narrower set, so a response that native hormone produces and the analog does not is suggestive of SSTR1, SSTR3 or SSTR4 involvement. Comparative work using both compounds is a common way to begin subtype attribution before moving to selective antagonists or receptor knockouts.

A further practical difference concerns rebound. The literature describes hormone rebound after abrupt withdrawal of short-acting somatostatin infusions, a phenomenon attributed to receptor and feedback adaptation during exposure. Longer-acting analogs change the exposure profile and therefore change what adaptation looks like in a given preparation.

How does octreotide compare with lanreotide and pasireotide?

All three are synthetic somatostatin analogs, and they differ mainly in receptor subtype affinity and in formulation strategy. Lanreotide is a cyclic octapeptide with a binding profile broadly similar to that described for octreotide, dominated by SSTR2 with secondary SSTR5 activity, and it is formulated as a long-acting preparation. Pasireotide is structurally distinct, a cyclohexapeptide, and its published affinity profile is broader: research describes substantially higher affinity at SSTR1, SSTR3 and especially SSTR5 than the octapeptide analogs show, with somewhat lower relative affinity at SSTR2.

That difference in coverage has predictable downstream consequences that the literature documents. Because SSTR5 signaling has a prominent role in insulin regulation, a broader analog weighted toward SSTR5 produces a different metabolic signature than one weighted toward SSTR2, and reports on glucose homeostasis differ between the compounds accordingly. In tumor biology, the subtype expressed by the tissue under study determines which analog engages it, which is why receptor expression profiling precedes analog selection in much of this research.

For laboratory comparison work, the three compounds function as a crude subtype dissection kit. Concordant responses across all three point to a receptor shared by their profiles, most often SSTR2. A response seen with the cyclohexapeptide but not the octapeptides points toward SSTR1, SSTR3 or SSTR5 involvement. The inference is suggestive rather than definitive, because affinity values are assay-dependent and because none of the three is truly monoselective.

Structural chemistry reinforces the point. The octapeptides retain the natural beta-turn motif in a constrained ring, so they mimic the hormone's principal contact surface closely. The cyclohexapeptide scaffold presents a different arrangement, which is how it achieves a different affinity pattern despite serving the same receptor family. Comparative pharmacology papers generally report full binding panels rather than single affinity values for this reason.

What does the published literature report about pharmacokinetics and formulations?

The published pharmacokinetic picture is dominated by one contrast: the analog persists far longer in circulation than the native hormone, with a half-life described in hours for the immediate-release form against minutes for somatostatin-14. That difference is the direct result of the structural modifications, and it is what made sustained pharmacology possible at all.

Even so, a half-life measured in hours is short relative to chronic conditions, which is why a long-acting depot formulation was developed. Depot preparations embed the peptide in a biodegradable polymer matrix from which it is released gradually over a period of weeks, producing a flatter exposure profile. Published descriptions of depot pharmacokinetics note an initial release phase followed by sustained release as the matrix degrades, and note that steady-state exposure is reached only after repeated intervals rather than immediately.

Distribution and clearance are also reported. The peptide binds plasma proteins to a moderate degree, distributes into a relatively small volume consistent with limited tissue penetration for a hydrophilic peptide, and is cleared by a combination of hepatic metabolism and renal elimination, with reports of altered clearance in renal impairment. Oral availability is negligible for the unmodified peptide, as it is for peptides generally, because gastrointestinal peptidases and poor epithelial permeability eliminate most of an orally presented amount before it can reach circulation.

Translating these figures into any schedule is outside what research reporting supports, and published values describe the pharmaceutical product in a clinical setting rather than a research chemical in a laboratory one. For in vitro work the relevant parameters are different anyway: stability in the culture medium over the exposure window, binding to plasticware, and whether receptor internalization during prolonged exposure is confounding the readout. Studies reporting time-dependent responses in culture generally characterize compound stability in parallel.

What safety and tolerability signals does the clinical literature describe?

The clinical literature on finished octreotide acetate products describes a recognizable set of tolerability signals, all of which follow from the breadth of secretory inhibition rather than from anything unique to this molecule. Gastrointestinal effects are the most commonly reported: abdominal discomfort, loose stools or steatorrhea from reduced pancreatic enzyme output, nausea and bloating. These are generally described as most prominent early in exposure.

Hepatobiliary effects are the signal most specific to this class. Suppression of cholecystokinin release reduces gallbladder contraction, and prolonged exposure is associated in the literature with biliary sludge and gallstone formation. Monitoring of gallbladder status during long-term clinical exposure is standard practice described in that literature for this reason.

Glucose handling is a third area. Because both insulin and glucagon are suppressed, the net glycemic effect depends on which hormone's suppression dominates in a given individual, and reports describe both hyperglycemia and hypoglycemia. Analogs with greater SSTR5 weighting are reported to shift this balance differently, which is one of the clearer illustrations of subtype selectivity producing a distinct clinical signature. Bradycardia and conduction changes have also been reported, as have effects on thyroid hormone regulation during long-term exposure.

None of this transfers to research-grade material, and none of it constitutes safety information for any non-clinical setting. It is reported here because an investigator interpreting an animal study needs to know which physiological systems the compound perturbs, so that an unexpected change in body weight, glucose or gastrointestinal function in a treated group is recognized as on-target pharmacology rather than attributed to the experimental variable under test. Research suggests these effects are consistent across species that express the relevant receptor subtypes, though magnitudes differ.

How is research-grade octreotide identified and documented?

Identity for a research peptide rests on analytical documentation rather than on a label claim. The expected molecular weight near 1,019 g/mol for the free peptide base, the formula C49H66N10O10S2 and the registry number 83150-76-9 together define what the material should be, and mass spectrometry against that mass is the primary identity check. Chromatographic analysis establishes the compositional profile of the lot and separates the intended peptide from process-related species such as deletion sequences, incompletely cyclized material or oxidation products. For a disulfide-bridged peptide, confirming that the intramolecular bridge has formed correctly matters, because the linear reduced form and the dimerized form have different masses and different activity.

Certificates of analysis record these results lot by lot, including net peptide content for salt preparations, so that a laboratory working from gross powder weight understands that the figure includes counterion and residual moisture. Real Peptides publishes independent third-party certificates of analysis for every batch at /coas/, and verifying registry number and molecular identity against that record before procurement is the ordinary diligence step for any catalog compound.

Concentration bookkeeping follows from net content. The arithmetic is simple: a container holding 5 mg of peptide taken into 5 mL of solvent gives a nominal concentration of 1 mg per mL, and the same container taken into 10 mL gives 0.5 mg per mL. Nominal is the operative word, since net peptide content below gross weight means the true concentration of active peptide is lower than the nominal figure unless the content value is applied. That is the whole of what concentration arithmetic says; it states no quantity anyone would use.

Lyophilized peptide powder is handled as a solid under cold, dry, light-protected conditions, which is the general practice for peptides of this class. Real Peptides provides no preparation or use guidance for any catalog compound, because these are research-use-only materials supplied for laboratory investigation.

What are the limits of the current evidence on octreotide?

The limits fall into three groups. The first is selectivity. Describing this compound as a somatostatin analog implies broader coverage than it has, and a result obtained with it speaks mainly to SSTR2 biology with an SSTR5 contribution. Experiments that attribute a finding to somatostatin signaling generally require a second analog with a different profile, a selective antagonist or a receptor-deficient model before the attribution is secure.

The second is species and model translation. Somatostatin receptor expression patterns differ between species and between tissues within a species, and an epithelial or endocrine response in rodent tissue need not predict the human response. The rat colonic work cited above is a clear instance: it establishes that an evoked secretory response in that preparation is sensitive to receptor activation, and it does not establish anything about human intestinal physiology, which the report itself does not claim.

The third is endpoint strength. Much of the human literature outside the approved indications consists of early-phase or uncontrolled work with biomarker endpoints. The phase II prostate cancer report is a good example of a well-conducted study whose readout is a circulating peptide axis rather than a clinical outcome, in a narrowly defined population without a randomized comparator. Biomarker movement is evidence of target engagement, and it is not evidence of benefit.

What survives all three caveats is a well-characterized core: a conformationally constrained octapeptide with a defined structure, a documented affinity profile weighted toward SSTR2 and SSTR5, a reproducible inhibitory effect on regulated secretion in receptor-expressing cells, and decades of use as a reference agonist in somatostatin receptor pharmacology. Studies report that core consistently. The open questions concern which downstream effects in complex systems belong to which receptor subtype, and how far biomarker engagement predicts anything beyond itself.

All compounds discussed on this page are sold for laboratory research use only and are not for human consumption.

References

Questions

Octreotide is a synthetic cyclic octapeptide analog of the hormone somatostatin. Eight residues, closed by a disulfide bridge, with two D-configuration amino acids and a threoninol C-terminus, give it far greater stability than the native hormone and preferential affinity for somatostatin receptor subtypes 2 and 5.
It occupies somatostatin receptors, mainly SSTR2 and SSTR5, which are G protein-coupled receptors linked to inhibitory signaling. Occupancy lowers intracellular cyclic AMP, opens potassium conductances and reduces calcium entry, so regulated hormone release from receptor-expressing cells falls. Growth hormone suppression is the best characterized example.
In approved clinical labeling, octreotide acetate products cover acromegaly and the symptomatic features of certain hormone-secreting neuroendocrine tumors. In laboratories, the compound serves as a receptor-selective agonist for probing somatostatin receptor signaling. Research-grade material supplied by Real Peptides has no clinical status and is for laboratory investigation only.
Approved labeling lists acromegaly, the severe diarrhea and flushing associated with metastatic carcinoid tumors, and the profuse watery diarrhea associated with vasoactive intestinal peptide secreting adenomas. Investigational and off-label reports describe many other applications, but that literature carries different and generally weaker evidentiary weight.
In the approved clinical setting it is given to suppress pathological hormone secretion in acromegaly and in defined hormone-secreting neuroendocrine tumors, along with the symptoms that secretion drives. In published laboratory studies it is given in experimental preparations to test whether a response depends on somatostatin receptor signaling.
It is a synthetic eight-residue somatostatin analog that works by binding somatostatin receptors, principally SSTR2 with secondary SSTR5 activity. Those receptors couple to inhibitory G proteins, so occupancy reduces cyclic AMP, hyperpolarizes the membrane and limits calcium-dependent secretory vesicle fusion, suppressing hormone release.
Octreotide acetate is the acetate salt of the same octapeptide, and the pharmacologically active species is identical once dissolved. The salt form handles and dissolves more predictably. Gross powder weight includes counterion and residual moisture, so net peptide content is reported lot by lot on the certificate of analysis.
No. A medicine is a finished pharmaceutical product made under pharmaceutical quality systems with approved labeling and regulatory status. Research-grade material is a characterized chemical supplied to laboratories for in vitro and preclinical investigation, with analytical documentation rather than an insert, and no approved indication of any kind.

RESEARCH USE ONLY · NOT EVALUATED BY THE FDA

Shop Now